Opto-Edu (Beijing) Co., Ltd.100043Bakit Tayo (指向 公司信息, 格式不好编辑, 另起一个页面Bakit Tayo)F-1501 Wanda Plaza, No.18 Shijingshan Road, Beijing 100043, ChinaOpto-Edu (Beijing) Co., Ltd.100043Bakit Tayo (指向 公司信息, 格式不好编辑, 另起一个页面Bakit Tayo)F-1501 Wanda Plaza, No.18 Shijingshan Road, Beijing 100043, ChinaOpto-Edu (Beijing) Co., Ltd.Opto-Edu (Beijing) Co., Ltd.Opto-Edu (Beijing) Co., Ltd.Opto-Edu (Beijing) Co., Ltd.Opto-Edu (Beijing) Co., Ltd.Opto-Edu (Beijing) Co., Ltd.Opto-Edu (Beijing) Co., Ltd.Opto-Edu (Beijing) Co., Ltd.Opto-Edu (Beijing) Co., Ltd.Opto-Edu (Beijing) Co., Ltd.Opto-Edu (Beijing) Co., Ltd.Opto-Edu (Beijing) Co., Ltd.Opto-Edu (Beijing) Co., Ltd.Opto-Edu (Beijing) Co., Ltd.Opto-Edu (Beijing) Co., Ltd.Opto-Edu (Beijing) Co., Ltd.Opto-Edu (Beijing) Co., Ltd.Opto-Edu (Beijing) Co., Ltd.Opto-Edu (Beijing) Co., Ltd.Opto-Edu (Beijing) Co., Ltd.Opto-Edu

Paano Pumili ng Mahahalagang Kagamitan sa Microscope: Mga Layunin, Eyepieces at Mechanical Stage?

Ang pagpili ng mga tamang accessory ng mikroskopyo ay nagsisimula sa tatlong priyoridad: pumili ng mga layunin na lente batay sa kinakailangang resolution, pumili ng mga eyepiece na nagbibigay ng kapaki-pakinabang na pag-magnify at isang naaangkop na larangan ng pagtingin, at pumili ng mekanikal na yugto na nagsisiguro ng matatag, tumpak na pagpoposisyon ng specimen. Ang lahat ng tatlong bahagi ay dapat na tugma sa optical at mechanical system ng mikroskopyo.

Para sa regular na biological at cell observation, ang isang praktikal na panimulang configuration ay binubuo ng 4x, 10x, 20x at 40x na layunin, 10x widefield eyepieces, at isang XY mechanical stage. Maaaring magdagdag ng 100× oil immersion na layunin kapag kailangan ang mas mataas na resolution na pagmamasid ng mga stained microorganism o pinong cellular structure.

Gayunpaman, ang pinakamahusay na mga accessory ng mikroskopyo ay hindi nangangahulugang ang may pinakamataas na pag-magnify, pinakamalaking numero ng field o pinaka-advanced na mekanikal na disenyo. Ang kanilang halaga ay depende sa kung pinapabuti nila ang kalidad, kahusayan at pagkakapare-pareho ng iyong aktwal na daloy ng trabaho sa pagmamasid.

Para sa mga laboratoryo, institusyong pang-edukasyon at mga distributor ng mikroskopyo, ang pag-unawa sa mga pamantayan sa pagpili na ito ay maaaring makatulong na maiwasan ang mga hindi tugmang pagbili, hindi kinakailangang pag-upgrade ng kagamitan at hindi magkatugma na mga resulta ng imaging.

1. Ano ang Mga Mahahalagang Accessory ng Microscope na Nararapat Puhunan?

Ang pinakamahalagang accessory ng mikroskopyo ay ang mga direktang nakakaimpluwensya sa kalidad ng imahe, kahusayan sa pagmamasid, pagiging maaasahan ng pagsukat at pagkakatugma ng aplikasyon.

Kabilang sa mga ito, ang mga object na lente, eyepiece at mekanikal na yugto ay dapat na karaniwang makatanggap ng priyoridad kapag nagko-configure o nag-a-upgrade ng compound biological microscope.

Accessory ng mikroskopyo

Pangunahing pag-andar

Pangunahing pamantayan sa pagbili

Priyoridad sa pagbili

Layunin na lente

Nilulutas ang mga detalye ng ispesimen

NA, magnification, optical correction, working distance

Mahalaga

Eyepiece

Pinapalaki ang intermediate na imahe

Magnification, field number, eye relief, compatibility

Mahalaga para sa visual na pagmamasid

Mekanikal na yugto

Kinokontrol ang pagpoposisyon ng ispesimen

XY travel, backlash, stability, specimen holder

Mahalaga para sa sistematikong pagmamasid sa slide

Condenser

Kinokontrol ang specimen illumination

NA, centering, contrast compatibility

Mahalagang optical component

Stage micrometer

Nag-calibrate ng mga sukat

Pagtatapos ng scale, katumpakan ng pagkakalibrate

Kinakailangan para sa quantitative measurements

Microscope camera

Kinukuha ang mga larawan at video

Laki ng sensor, laki ng pixel, optical adapter

Nakadepende sa aplikasyon

Mga accessory ng phase contrast

Pagbutihin ang kaibahan sa mga transparent na specimen

Pagtutugma ng layunin at condenser annulus

Inirerekomenda para sa hindi nabahiran na mga buhay na selula

Mga accessory ng fluorescence

Paganahin ang pagmamasid na nakabatay sa fluorescence

Spectral compatibility, pag-iilaw, pagsasaayos ng filter

Nakadepende sa aplikasyon

Aling microscope accessory ang dapat mong i-upgrade muna?

Ang sagot ay depende sa limitasyon ng iyong umiiral na mikroskopyo.

Kung ang mga pinong istruktura ng cellular ay mananatiling hindi nalutas, ang layunin at sistema ng pag-iilaw ay dapat na masuri muna. Ang pagtaas ng eyepiece magnification ay malamang na hindi makalutas ng problema sa optical resolution.

Kung matalas ang larawan ngunit masyadong maliit ang nakikitang bahagi, maaaring mapabuti ng katugmang eyepiece na may mas malaking field number ang kahusayan sa pagmamasid.

Kung ang mga specimen ay mahirap hanapin, malamang na lumipat sa panahon ng pagmamasid o hindi maaaring muling iposisyon nang tuluy-tuloy, ang pag-upgrade sa mekanikal na yugto ay maaaring maghatid ng mas praktikal na halaga kaysa sa pagbili ng mas mataas na antas na layunin.

Problema sa iyong kasalukuyang mikroskopyo

Inirerekomendang direksyon sa pagbili

Ang mga magagandang istraktura ay hindi maaaring makilala

Layunin ng mas mataas na NA at katugmang condenser

Malaki ang larawan ngunit walang detalye

I-optimize ang layunin at eyepiece magnification

Malabo ang mga gilid ng larawan na dulot ng field curvature

Layunin na naitama sa plano

Hindi sapat na saklaw ng ispesimen

Mas malawak na field na eyepiece o lower-magnification na layunin

Kahirapan sa paghahanap ng mga partikular na cell

Precision XY mekanikal na yugto

Mahina ang kakayahang makita ng mga hindi nabahiran na mga selula

Katugmang phase contrast accessories

Hindi makapag-focus sa pamamagitan ng isang culture vessel

Long-working-distance na layunin na idinisenyo para sa sisidlan

Hindi pare-pareho ang mga sukat ng cell

Naka-calibrate na reticle o imaging system

Mga hindi pare-parehong resulta sa maraming workstation

Standardized na mga configuration ng accessory

Ang isang cost-effective na diskarte sa pagbili ay nagsisimula sa pamamagitan ng pagtukoy sa aktwal na performance bottleneck sa halip na palitan ang bawat accessory nang sabay-sabay.

2. Paano Pumili ng Microscope Objective Lens

Kapag pumipili ng mga objective lens, unahin ang numerical aperture, optical correction, working distance at system compatibility bago isaalang-alang ang maximum magnification.

Ang wastong napiling 40× na layunin ay maaaring magbigay ng mas kapaki-pakinabang na impormasyon ng ispesimen kaysa sa isang hindi magandang tugmang 60× o 100× na layunin.

2.1 Pumili ng layunin magnification ayon sa ispesimen

Tinutukoy ng Objective magnification ang sukat ng intermediate na imahe at naiimpluwensyahan kung gaano karami ng ispesimen ang maaaring maobserbahan sa isang pagkakataon.

Ang iba't ibang gawain sa pagmamasid ay nangangailangan ng iba't ibang balanse sa pagitan ng saklaw ng specimen at fine-detail na visibility.

Pagpapalaki ng layunin

Karaniwang aplikasyon

Kabuuang magnification na may 10x eyepiece

Karaniwang layunin ng pagbili

4×

Buong-slide na oryentasyon, pangkalahatang-ideya ng tissue

40×

Mabilis na lokasyon ng ispesimen

10×

Pamamahagi ng cell, organisasyon ng tissue

100×

Pangkalahatang screening

20×

Cell morpolohiya, kultural na pagmamasid sa cell

200×

Balanse sa pagitan ng saklaw at detalye

40×

Nuclei, cellular morphology, stained specimens

400×

Detalyadong biological na pagmamasid

60×

Mga pinong istruktura ng cellular

600×

Advanced na pagmamasid sa laboratoryo

100 × langis

May bahid na bakterya, pinong morphological na katangian

1000×

High-resolution na pagmamasid

Para sa mga pang-edukasyon na mikroskopyo, ang isang 4x, 10x at 40x na pagsasaayos ng layunin ay kadalasang sapat para sa mga pangunahing eksperimento sa biology.

Para sa mga mikroskopyo ng laboratoryo, ang pagdaragdag ng 20x na layunin ay maaaring maging partikular na mahalaga. Nagbibigay ito ng intermediate na hakbang sa pagmamasid nang hindi nangangailangan ng mga user na direktang lumipat mula sa 100× hanggang 400× na kabuuang magnification.

Para sa mga microbiology laboratories, ang 100× oil immersion na layunin ay kadalasang kinakailangan kapag ang gawain sa pagmamasid ay nangangailangan ng mas pinong morphological na detalye.

Gayunpaman, ang mas mataas na pag-magnify ay hindi nagtatatag kung ang isang partikular na istraktura ay talagang malulutas.

2.2 Mas mahalaga ang numerical aperture kaysa sa maximum magnification

Ang numerical aperture (NA) ay isa sa pinakamahalagang teknikal na detalye kapag bumibili ng mga layunin ng mikroskopyo. Inilalarawan nito ang kakayahan ng layunin na mangolekta ng liwanag sa isang angular na hanay at direktang nag-aambag sa kakayahan nitong paglutas.

Ang numerical aperture ay ipinahayag bilang:

NA = n × kasalanan θ

saan:

  • n ay ang refractive index ng medium sa pagitan ng specimen assembly at layunin.

  • Ang θ ay ang kalahating anggulo ng nakolektang light cone.

Ang karaniwang ginagamit na approximation ng lateral optical resolution, sa ilalim ng angkop na diffraction-limited imaging condition, ay ang Rayleigh criterion:

d = (0.61 × λ) / NA

saan:

  • d ay kumakatawan sa pinakamababang nareresolba na distansya.

  • Ang λ ay kumakatawan sa wavelength ng liwanag.

  • Kinakatawan ng NA ang numerical aperture ng layunin.

Ang isang mas maliit na halaga ng resolution ay nagpapahiwatig ng isang mas malawak na teoretikal na kakayahan upang makilala ang malapit na pagitan ng mga tampok.

Ang sumusunod na paghahambing ay gumagamit ng kinatawan na mga pagtutukoy ng layunin at isang reference na wavelength na 550 nm, katumbas ng 0.55 μm.

Layunin

Kinatawan NA

Kinakalkula ang lateral na resolusyon

4× Achromat

0.10

3.36 μm

10× Achromat

0.25

1.34 μm

20× Achromat

0.40

0.84 μm

40× Achromat

0.65

0.52 μm

40x mas mataas na layunin ng NA

0.95

0.35 μm

60 × layunin

0.85

0.39 μm

100× Langis

1.25

0.27 μm

100× mataas na NA Langis

1.40

0.24 μm

Halimbawa, ang teoretikal na pag-ilid na resolusyon ng isang 40x na layunin na may NA na 0.65 ay maaaring kalkulahin tulad ng sumusunod:

d = (0.61 × 0.55) / 0.65

d ≈ 0.516 μm

Theoretical lateral resolution ≈ 0.52 μm

Fluorescence microscopy images comparing 40× objectives with numerical apertures of 0.60, 0.95 and 1.30 for mitochondrial imaging

Parehong Magnification, Iba't ibang Numerical Aperture: 40× Paghahambing ng Resolution ng Layunin

Isaalang-alang ang dalawang layunin na madalas na sinusuri sa panahon ng pagkuha ng kagamitan sa laboratoryo:

Pagtutukoy

Layunin A

Layunin B

Pagpapalaki

40×

60×

Numerical aperture

0.95

0.85

Kinalkula na resolution

0.353 μm

0.395 μm

Kabuuang magnification na may 10x eyepiece

400×

600×

Ang teoretikal na resolusyon ng bawat layunin ay maaaring kalkulahin tulad ng sumusunod:

Layunin A:

d(A) = (0.61 × 0.55) / 0.95 ≈ 0.353 μm

Layunin B:

d(B) = (0.61 × 0.55) / 0.85 ≈ 0.395 μm

Ang pagbawas sa pinakamababang nareresolba na distansya ay maaaring kalkulahin gamit ang mga unrounded value:

Pagbawas (%) = [1 − (0.85 / 0.95)] × 100%

Pagbawas ≈ 10.5%

Bagama't ang Layunin B ay nagbibigay ng mas malaking pagpapalaki, ang Layunin A ay may humigit-kumulang 10.5% na mas maliit na teoretikal na pinakamababang nareresolba na distansya sa ilalim ng parehong mga kondisyon ng pagkalkula.

Ito ay naglalarawan kung bakit ang pagbili ng isang mas mataas na-magnification layunin ay hindi nangangahulugang naghahatid ng mas mahusay na optical resolution.

Rekomendasyon sa pagbili: Palaging hilingin ang numerical aperture ng bawat layunin kapag naghahambing ng mga panipi. Dalawang layunin na may magkaparehong pag-magnify ay maaaring magkaroon ng malaking magkaibang kakayahan sa optical.

Ang aktwal na pagganap ng paglutas ay nakasalalay din sa pag-iilaw, condenser aperture, optical alignment, paghahanda ng specimen, contrast at aberration correction. Kaya dapat ituring ang mga kinakalkula na halaga bilang mga teoretikal na paghahambing sa halip na mga garantisadong resulta ng pagsubok.

2.3 Piliin ang naaangkop na optical correction grade

Nag-iiba ang mga layunin ng mikroskopyo sa kung gaano kabisa nilang itama ang chromatic aberration, spherical aberration at field curvature.

Ang naaangkop na grado ng pagwawasto ay depende sa kung ang mikroskopyo ay gagamitin para sa karaniwang pagmamasid, imaging, quantitative analysis o advanced na pananaliksik.

Uri ng layunin

Mga katangian ng optical

Inirerekomendang mga aplikasyon

Kamag-anak na gastos

Achromatic

Pangunahing chromatic at spherical correction

Edukasyon, regular na pagmamasid

Mababa

Plan Achromatic

Achromatic correction na may pinahusay na field flatness

Mga regular na laboratoryo, digital imaging

Katamtaman

Fluorite / Semi-Apochromatic

Pinahusay na pagwawasto ng aberration

Advanced na biological at fluorescence imaging

Katamtaman–Mataas

Plano ang Fluorite

Pinahusay na pagwawasto at field flatness

Cell imaging, fluorescence, pagsusuri ng imahe

Mataas

Plano Apochromatic

Advanced na chromatic correction at field flatness

Advanced na pananaliksik at hinihingi ang imaging

Mataas–Napakataas

10× Achromat vs. 10× Plan Achromat

10× Achromat kumpara sa 10× Plan Achromat

Kailan sapat ang mga achromatic na layunin?

Ang mga achromatic na layunin ay karaniwang angkop para sa pagtuturo sa mga laboratoryo at mga nakagawiang aplikasyon kung saan pangunahing sinusuri ng operator ang mga istrukturang malapit sa gitna ng visual field.

Para sa mga institusyong bumibili ng malalaking dami ng mga pang-edukasyon na mikroskopyo, nag-aalok sila ng praktikal na balanse sa pagitan ng optical performance at gastos sa pagkuha.

Kailan ka dapat bumili ng plan achromatic na mga layunin?

Ang mga layunin ng achromatic na plano ay isang partikular na kapaki-pakinabang na pag-upgrade para sa mga laboratoryo na madalas na kumukuha ng mga larawan ng digital na mikroskopyo, sinusuri ang mga specimen sa isang malawak na larangan o nagsasagawa ng sistematikong pagbibilang ng cell.

Ang field curvature ay nagiging sanhi ng iba't ibang mga rehiyon ng isang imahe na tumuon sa iba't ibang mga focal position. Binabawasan ng pagwawasto ng plano ang problemang ito sa larangan ng larawang idinisenyo ng layunin.

Halimbawa, kapag nagmamasid sa isang flat stained tissue section, ang isang karaniwang layunin ay maaaring makabuo ng isang matalas na gitnang imahe habang nangangailangan ng muling pagtutok sa mga gilid. Ang isang angkop na layunin ng plano ay maaaring mapabuti ang pagkakapare-pareho ng focus-to-edge.

Ito ay lalong mahalaga para sa pagtatahi ng imahe at awtomatikong pagsusuri, bagama't ang mga application na iyon ay nangangailangan din ng naaangkop na pag-iilaw, pagkakalibrate ng camera at katumpakan ng entablado.

Sulit ba sa karagdagang pamumuhunan ang mga layunin ng apochromatic na plano?

Mabibigyang-katwiran ang mga ito kapag ang aplikasyon ay nangangailangan ng advanced na multi-wavelength na imaging, mataas na resolution na pag-obserba ng fluorescence o mas hinihingi na pagwawasto ng mga chromatic aberration.

Para sa nakagawiang pagtuturo at pangunahing pagmamasid sa cell morphology, gayunpaman, ang kanilang karagdagang gastos ay maaaring hindi maghatid ng isang proporsyonal na pagpapabuti sa daloy ng trabaho.

Ang mga terminong plano, achromatic at apochromatic ay hindi dapat bigyang-kahulugan bilang mga mapagpapalit na tagapagpahiwatig ng kalidad ng optical. Dapat na hiwalay na suriin ang field flatness, chromatic correction at numerical aperture.

2.4 Piliin ang tamang distansya sa pagtatrabaho

Ang distansya sa pagtatrabaho ay ang distansya sa pagitan ng harap ng layunin at ang ispesimen o takip na ibabaw ng salamin na nakatutok, ayon sa disenyo ng layunin.

Ito ay nagiging partikular na mahalaga kapag nagmamasid sa makapal na mga ispesimen, mga ispesimen sa loob ng mga lalagyan o mga buhay na selula sa mga sisidlan ng kultura.

Ispesimen o aplikasyon

Inirerekomenda na mga katangian ng layunin

Mga karaniwang inihandang slide

Karaniwang biyolohikal na layunin

High-magnification stained slides

Maaaring katanggap-tanggap ang layunin ng short-working-distance

Makapal na basang mga bundok

Sapat na distansya sa pagtatrabaho para sa paghahanda

Mga nabubuhay na selula sa mga lutuing pangkultura

Long-working-distance, vessel-compatible na layunin

Mga eksperimento sa pagmamanipula ng cell

Pinalawak na distansya sa pagtatrabaho

Pagmamasid sa multiwell plate

Naitama ang layunin para sa kapal ng plate-bottom

Ang mga layunin ng high-NA ay karaniwang may mas maiikling distansya sa pagtatrabaho, bagama't ang mga espesyal na disenyo ay maaaring pahabain ang distansya sa pagtatrabaho upang mapaunlakan ang mga partikular na aplikasyon.

Bago bumili ng layunin para sa cell culture, tukuyin ang kapal at materyal ng ilalim ng sisidlan, ang kinakailangang lalim ng pagmamasid at ang magagamit na clearance.

Ang isang high-NA na layunin na hindi maabot ang focal plane ng specimen ay walang praktikal na halaga ng pagbili, anuman ang teoretikal na resolusyon nito.

2.5 Suriin ang kapal ng coverslip at mga kondisyon ng pag-mount ng specimen

Ang isang madalas na hindi napapansing layunin ng pagtutukoy ay ang kapal ng takip ng salamin kung saan ang lens ay optically corrected.

Maraming karaniwang biological na layunin ang idinisenyo sa paligid ng isang nominal na coverslip na kapal na 0.17 mm.

Sa mas mataas na mga numerical aperture, ang mga pag-alis mula sa nilalayong optical na kapal ay maaaring makabuluhang tumaas ang spherical aberration.

Ang teknikal na talakayan ng Nikon tungkol sa pagwawasto ng coverslip ay naglalarawan na ang mga high-NA dry na layunin ay maaaring maging partikular na sensitibo sa medyo maliit na mga paglihis mula sa kanilang nilalayon na kapal ng takip ng salamin.

Ipinapaliwanag nito kung bakit ang isang mamahaling layunin na may mataas na NA ay maaaring makagawa ng mga nakakadismaya na larawan kapag ginamit sa hindi angkop na paghahanda ng ispesimen.

Bago mag-order, tukuyin kung ang mga sample ay magiging:

  • Naka-mount sa ilalim ng maginoo na takip na salamin.

  • Obserbahan nang walang takip na salamin.

  • Nakaposisyon sa loob ng plastic culture vessel.

  • Naobserbahan sa pamamagitan ng isang glass-bottom dish.

  • Naka-mount sa isang medium na may tinukoy na refractive index.

Para sa mga application na kinasasangkutan ng mga variable na optical thickness, ang isang layunin na nilagyan ng correction collar ay maaaring isang mas angkop na pamumuhunan.

Ang isang kwelyo ng pagwawasto ay hindi isang unibersal na solusyon, gayunpaman. Ang magagamit na hanay ng pagsasaayos ay dapat tumanggap ng aktwal na pagsasaayos ng sample.

2.6 Pumili sa pagitan ng tuyo at immersion na mga layunin

Ang pagpili sa pagitan ng tuyo at immersion na mga lente ay dapat na nakabatay sa kinakailangang resolusyon at mga hinihingi sa pagpapatakbo ng laboratoryo.

Salik sa pagpili

Tuyong layunin

Layunin ng oil immersion

Layunin ng paglulubog sa tubig

daluyan ng pagsasawsaw

Hangin

Tinukoy na immersion oil

Tubig

Mga karaniwang application

Regular na biological na pagmamasid

High-resolution na thin specimen imaging

May tubig at buhay na biological imaging

Pagpapanatili

Medyo simple

Nangangailangan ng paglilinis ng langis

Nangangailangan ng katamtamang pamamahala

Maximum na matamo NA

Limitado ng air refractive index

Maaaring lumampas sa 1.0

Maaaring lumampas sa 1.0

Ang pagiging kumplikado ng pagpapatakbo

Mababa

Katamtaman

Nakadepende sa aplikasyon

Mga inirerekomendang user

Mga paaralan at regular na laboratoryo

Microbiology at advanced na mga laboratoryo

Espesyal na biolohikal na pananaliksik

Ang benepisyo ng immersion optics ay nagmumula sa kanilang optical na disenyo at sa mga repraktibo na katangian ng tinukoy na medium ng immersion.

Ang karaniwang immersion oil ay karaniwang may refractive index na malapit sa 1.51, na nagbibigay-daan sa angkop na idinisenyong layunin upang mangolekta ng mga sinag na kung hindi man ay malilimitahan ng air gap.

Gayunpaman, ang oil immersion ay nagpapakilala ng mga karagdagang kinakailangan sa paglilinis at ang posibilidad na makontamina ang mga katabing layunin.

Para sa mga laboratoryo na nagpoproseso ng maraming nakagawiang specimen, ang isang mataas na kalidad na 40x na tuyo na layunin ay maaaring magbigay ng higit na kahusayan sa pagpapatakbo kaysa sa regular na paglipat sa isang layunin sa paglulubog.

Ang isang daluyan ng immersion ay hindi dapat palitan nang basta-basta. Ang langis, tubig at iba pang immersion media ay hindi maaaring palitan maliban kung ang layunin ng tagagawa ay partikular na pinahihintulutan ang kanilang paggamit.

2.7 I-verify ang layunin ng compatibility bago bumili

Ang mga layunin ng mikroskopyo ay hindi mapagpalit sa pangkalahatan.

Kahit na ang mga layunin na may magkaparehong mga mounting thread at magnification ay maaaring hindi magkatugma dahil ang kanilang mga optical correction system, mekanikal na haba at mga kinakailangan sa tube lens ay naiiba.

Parameter ng compatibility

Ano ang dapat i-verify

Optical system

Finite-conjugate o infinity-corrected

Haba ng mekanikal na tubo

Halimbawa, 160 mm kung saan tinukoy

Tube lens focal length

Kinakailangan ng optical system ng tagagawa

Layunin mounting thread

RMS, M25, M27 o iba pang tinukoy na thread

Parfocal na distansya

Distansya mula sa mounting reference surface hanggang specimen plane

Pagwawasto ng salamin sa takip

0.17 mm, walang takip na salamin o tinukoy na saklaw

daluyan ng pagsasawsaw

Hangin, langis, tubig o iba pang tinukoy na daluyan

Contrast technique

Brightfield, phase contrast, fluorescence o iba pa

Nawastong field ng larawan

Pagkatugma sa eyepiece at imaging system

Pisikal na clearance

Layunin diameter, nosepiece spacing at working distance

Simplified optical paths illustrating why finite and infinity-corrected objectives cannot be substituted directly

Sa isang infinity-corrected microscope, ang layunin ay gumagana sa isang hiwalay na tube lens upang makagawa ng intermediate na imahe. Maaaring baguhin ng hindi tugmang tube lens ang epektibong pag-magnify at ikompromiso ang aberration correction.

Halimbawa, ang layunin ng infinity na idinisenyo para sa isang 200 mm na tube lens ay maaaring makabuo ng ibang epektibong magnification kapag ginamit sa isang 180 mm na tube lens.

Ang mabisang pagpapalaki ay maaaring matantya gamit ang sumusunod na formula:

Effective Magnification = Nominal Objective Magnification × (Actual Tube Lens Focal Length / Designed Tube Lens Focal Length)

Para sa isang nominal na 40x na layunin:

Nominal Objective Magnification = 40×

Dinisenyong Tube Lens Focal Length = 200 mm

Aktwal na Tube Lens Focal Length = 180 mm

Epektibong Magnification = 40 × (180 / 200)

Mabisang Magnification = 36×

Ang pagkalkulang ito ay naglalarawan lamang ng pagbabago sa pag-magnify. Hindi nito itinatag na ang resultang optical system ay mananatili sa orihinal nitong kalidad ng imahe.

Para sa mga kapalit na layunin, bigyan ang supplier ng umiiral na tagagawa ng mikroskopyo, numero ng modelo, mga marka ng layunin at mga detalye ng optical system.

Sa OPTO EDU, maaaring tuklasin ng mga mamimili angA52 Microscope Layunin kategoryaat kumunsulta sa technical sales team para matukoy ang mga angkop na opsyon para sa kanilang kagamitan at mga kinakailangan sa pagmamasid.

3. Paano Pumili ng Microscope Eyepieces

Para sa karamihan ng mga biological microscope, ang 10× widefield eyepieces ay nagbibigay ng praktikal na balanse sa pagitan ng magnification, field of view at viewing comfort. Ang mga eyepiece na may mataas na pag-magnify ay dapat lamang bilhin kapag ang kakayahan sa paglutas ng layunin at ang gawain sa pagmamasid ay nagbibigay-katwiran sa kanilang paggamit.

Kapag pumipili ng eyepieces, dapat suriin ng mga mamimili ang limang parameter: magnification, field number, eye relief, optical correction compatibility at mounting diameter.

3.1 Pumili ng eyepiece magnification batay sa kapaki-pakinabang na magnification

Para sa isang conventional compound microscope na walang karagdagang intermediate magnification, ang kabuuang visual magnification ay kinakalkula bilang:

Kabuuang Magnification = Layunin Magnification × Eyepiece Magnification

Halimbawa, ang isang 40× na layunin na pinagsama sa isang 10× na eyepiece ay nagbibigay ng 400× na kabuuang pag-magnify.

Kabuuang Magnification = 40 × 10 = 400×

Ang pagpapalit ng 10× eyepiece ng isang 25× na eyepiece ay nagpapataas ng kabuuang magnification sa 1000×.

Kabuuang Magnification = 40 × 25 = 1000×

Gayunpaman, hindi ito nangangahulugan na maaaring malutas ng mikroskopyo ang mga karagdagang istruktura ng cellular.

Tinutukoy ng malawakang ginagamit na optical guideline ang kapaki-pakinabang na hanay ng pag-magnify bilang:

Kapaki-pakinabang na Saklaw ng Magnification ≈ 500 × NA hanggang 1000 × NA

Halimbawa, para sa 40x na layunin na may NA na 0.65:

Minimum Useful Magnification ≈ 500 × 0.65 = 325×

Maximum Useful Magnification ≈ 1000 × 0.65 = 650×

Inirerekomendang Kapaki-pakinabang na Saklaw ng Magnification: 325×–650×

Ang pag-magnify na lampas sa saklaw na ito ay maaaring magdulot ng walang laman na pag-magnify: isang mas malaking larawan na walang karagdagang nalutas na impormasyon ng ispesimen. Ang hanay na ito ay isang praktikal na patnubay sa halip na isang ganap na optical limit.

Layunin

NA

Tinatayang kapaki-pakinabang na pagpapalaki

May 10x eyepiece

May 20× eyepiece

May 25× eyepiece

4×

0.10

50–100×

40×

80×

100×

10×

0.25

125–250×

100×

200×

250×

20×

0.40

200–400×

200×

400×

500×

40×

0.65

325–650×

400×

800×

1000×

60×

0.85

425–850×

600×

1200×

1500×

100× Langis

1.25

625–1250×

1000×

2000×

2500×

Ipinapakita ng talahanayan kung bakit ang isang pares ng high-magnification eyepieces ay hindi kinakailangang angkop para sa bawat layunin sa isang mikroskopyo.

Ang mas mababang pag-magnify ay nananatiling kapaki-pakinabang para sa specimen navigation at screening kahit na mas mababa ang mga ito sa inirerekomendang hanay para sa pagtingin sa pinakamagagandang available na mga detalye.

Para sa mga distributor, ang pagbili ng mga microscope na ibinebenta pangunahin sa paligid ng mga detalye tulad ng 2000x o 2500x na maximum na pag-magnify ay maaaring mapanlinlang kung ang layunin na NA ay hindi sumusuporta sa makabuluhang karagdagang detalye.

Ang isang mahusay na na-configure na 1000 × mikroskopyo ay maaaring magbigay ng mas praktikal na pagganap ng optical kaysa sa isang instrumento na ina-advertise na may mas mataas na kabuuang pag-magnify.

3.2 Suriin ang field number, hindi lang magnification

Tinutukoy ng field number (FN) ang diameter ng intermediate na imahe na nakikita sa pamamagitan ng eyepiece.

Para sa isang katugmang optical system na walang karagdagang intermediate magnification, ang specimen-plane field diameter ay maaaring matantya gamit ang:

Field of View Diameter (mm) = Field Number (FN) / Objective Magnification

Ang isang mas malaking field number ay nagbibigay-daan sa observer na suriin ang isang mas malaking specimen area nang hindi binabago ang layunin na magnification, sa kondisyon na ang optical system ng mikroskopyo ay sumusuporta sa mas malawak na field.

Layunin

FN18 eyepiece

FN20 eyepiece

FN22 eyepiece

FN25 eyepiece

4×

4.50 mm

5.00 mm

5.50 mm

6.25 mm

10×

1.80 mm

2.00 mm

2.20 mm

2.50 mm

20×

0.90 mm

1.00 mm

1.10 mm

1.25 mm

40×

0.45 mm

0.50 mm

0.55 mm

0.625 mm

100×

0.18 mm

0.20 mm

0.22 mm

0.25 mm

Gaano karaming pagpapabuti ang maibibigay ng mas malawak na field na eyepiece?

Isaalang-alang ang pag-upgrade mula sa isang 10×/18 mm eyepiece sa isang 10×/22 mm na eyepiece habang pinapanatili ang parehong 40× na layunin.

Ang nakikitang diameter ng ispesimen ay tumataas mula 0.45 mm hanggang 0.55 mm.

Orihinal na Field Diameter = 18 / 40 = 0.45 mm

Bagong Field Diameter = 22 / 40 = 0.55 mm

Dahil ang nakikitang field ay humigit-kumulang pabilog, ang lugar nito ay kinakalkula bilang:

A = π × (D / 2)²

saan:

  • Ang A ay kumakatawan sa nakikitang specimen area.

  • Ang D ay kumakatawan sa lapad ng field ng view.

  • π ≈ 3.14159.

Ang nakikitang specimen area na may FN18 eyepiece ay:

Orihinal na Field Area = π × (0.45 / 2)²

Orihinal na Field Area ≈ 0.1590 mm²

Ang nakikitang specimen area na may FN22 eyepiece ay:

Bagong Field Area = π × (0.55 / 2)²

Bagong Field Area ≈ 0.2376 mm²

Ang teoretikal na pagtaas sa nakikitang lugar ng ispesimen ay:

Pagtaas ng Field Area (%) = [(Bagong FN / Orihinal na FN)² − 1] × 100%

Pagtaas ng Field Area = [(22 / 18)² − 1] × 100%

Pagtaas ng Field Area = (1.4938 − 1) × 100%

Pagtaas ng Field Area ≈ 49.4%

Relative FOV Comparison for Different FN and Area with Light Microscopy

Sa madaling salita, ang pag-upgrade mula sa FN18 hanggang FN22 ay maaaring tumaas ang nakikitang specimen area ng humigit-kumulang 49.4% nang hindi binabawasan ang layunin ng paglaki.

Ito ay maaaring maging partikular na mahalaga para sa pagsusuri ng tissue, pagtatasa ng pamamahagi ng cell, paghahanap ng mga bihirang istruktura at paulit-ulit na pagsusuri sa slide.

Gayunpaman, ang pagkalkula na ito ay kumakatawan sa geometric field coverage, hindi isang sinusukat na pagpapabuti sa pagiging produktibo ng laboratoryo. Ang mga aktwal na benepisyo ay nakasalalay sa katas ng gilid, pamamahagi ng sample at ang pamamaraan ng pagmamasid.

3.3 Pumili ng eyepieces para sa pangmatagalang pagmamasid

Para sa mga laboratoryo kung saan gumugugol ang mga operator ng mahabang panahon sa pagsusuri sa mga slide, ang ergonomya ng eyepiece ay maaaring kasinghalaga ng magnification.

Ang kaluwagan sa mata ay ang distansya kung saan maaaring iposisyon ng tagamasid ang mata habang nakikita pa rin ang nilalayon na larangan. Ang high-eye-point eyepieces ay maaaring maging partikular na kapaki-pakinabang para sa mga operator na may suot na salamin.

Ang mga adjustable na diopter ay isa pang mahalagang pagsasaalang-alang, lalo na kapag maraming operator ang nagbabahagi ng parehong mikroskopyo. Pinapayagan nila ang mga user na magbayad para sa mga pagkakaiba sa mga kinakailangan sa pagtutok sa pagitan ng kanilang mga mata.

Tampok ng eyepiece

Benepisyo sa pagbili

Inirerekomendang aplikasyon

10x magnification

Balanseng visual na pagganap

Pangkalahatang mikroskopya

FN18–20

Matipid na saklaw ng larangan

Pang-edukasyon na mikroskopyo

FN22–25

Mas malawak na saklaw ng specimen kapag sinusuportahan

Mga regular at advanced na laboratoryo

Mataas na punto ng mata

Pinahusay na accessibility para sa mga nagsusuot ng salamin

Nakabahagi at matagal na pagmamasid

Naaayos na diopter

Indibidwal na visual na pagsasaayos

Mga laboratoryo ng maraming gumagamit

May hawak ng reticle

Sinusuportahan ang mga sukat ng pagsukat

quantitative microscopy

Mga eyecup

Tumutulong na pamahalaan ang panlabas na liwanag at pagpoposisyon ng mata

Pinalawak na pagmamasid

Para sa maramihang pagbili sa laboratoryo, ang mga ergonomic na feature ay maaaring magkaroon ng mas malaking pangmatagalang halaga kaysa sa mga detalyeng pang-promosyon na nagbibigay-diin sa maximum na pag-magnify.

3.4 Pumili ng panukat na eyepieces kapag kinakailangan ang quantitative data

Ang isang karaniwang eyepiece ay nagbibigay-daan sa visual na pagmamasid, ngunit hindi ito nagbibigay ng isang maaasahang paraan ng pagsukat ng mga cell.

Kung ang aplikasyon ay nagsasangkot ng diameter ng cell, kapal ng hibla o mga sukat ng microorganism, dapat isaalang-alang ang isang katugmang panukat na eyepiece na may ocular reticle at isang naka-calibrate na stage micrometer.

Ang kadahilanan ng pagkakalibrate ay maaaring kalkulahin gamit ang:

Calibration Factor (μm/division) = Kilalang Stage Micrometer Distansya (μm) / Bilang ng Ocular Division

Ipagpalagay na ang 50 ocular division ay tumutugma sa 100 μm sa isang stage micrometer.

Ang bawat ocular division ay kumakatawan sa:

Calibration Factor = 100 μm / 50

Calibration Factor = 2 μm/dibisyon

Kung ang isang cell ay sumasaklaw sa pitong ocular division, ang tinantyang sukat nito ay maaaring kalkulahin tulad ng sumusunod:

Aktwal na Laki ng Ispesimen = Bilang ng mga Ocular Division × Calibration Factor

Aktwal na Laki ng Cell = 7 × 2 μm

Aktwal na Laki ng Cell = 14 μm

Nagbabago ang calibration factor kapag nagbago ang layunin o intermediate magnification. Dahil dito, ang bawat pagsasaayos ng pagsukat ay dapat na i-calibrate nang hiwalay.

Para sa mga laboratoryo na nangangailangan ng mga dokumentadong sukat, ang digital imaging software na na-calibrate gamit ang isang stage micrometer ay maaaring mas angkop kaysa sa manu-manong pagsukat ng eyepiece lamang.

3.5 Suriin ang pagiging tugma ng eyepiece

Kasama sa mga karaniwang diameter ng pagpapasok ng eyepiece ang 23.2 mm, 30 mm at 30.5 mm, ngunit ang pisikal na diameter lamang ay hindi nagtatatag ng optical compatibility.

Bago bumili ng kapalit na eyepieces, i-verify ang insertion diameter, optical correction requirements, suportadong field number, reticle dimension at kung ang eyepiece ay inilaan para sa isang compound o stereo microscope.

Para sa mga binocular microscope, ang pagbili ng mga katugmang eyepiece ay karaniwang mas mainam kaysa sa paghahalo ng mga eyepiece na may iba't ibang optical na disenyo.

Ang OPTO EDU ay nagbibigay ng mga opsyon sa microscope eyepiece sa pamamagitan nitoA51 kategorya ng eyepiece. Ang mga mamimili na nagpapalit ng mga kasalukuyang eyepiece ay dapat magbigay ng kanilang modelo ng mikroskopyo at orihinal na mga marka ng eyepiece bago humiling ng isang panipi.

4. Paano Pumili ng Mechanical Stage para sa Microscope

Ang isang angkop na mekanikal na yugto ay dapat ilipat ang ispesimen nang maayos, hawakan ito nang ligtas at pahintulutan ang operator na mahanap o bisitahin muli ang mga lugar ng interes nang walang hindi kinakailangang muling pagpoposisyon.

Habang tinutukoy ng mga layunin ang optical na impormasyon na makukuha mula sa isang ispesimen, ang mga mekanikal na yugto ay nakakaimpluwensya kung gaano kabisang maa-access ang impormasyong iyon.

Para sa regular na pagmamasid sa cell, ang isang matatag na manu-manong pinatatakbo na XY na mekanikal na yugto ay karaniwang sapat. Para sa awtomatikong pagbibilang ng cell, paulit-ulit na imaging, pag-scan ng slide at mga eksperimento sa multiposition, maaaring kailanganin ang isang motorized na yugto na may dokumentadong pagganap sa pagpoposisyon.

4.1 Piliin ang tamang uri ng yugto ng mikroskopyo

Ang iba't ibang disenyo ng yugto ay inilaan para sa iba't ibang mga daloy ng trabaho sa pagmamasid.

Uri ng entablado

Pangunahing katangian

Angkop na mga aplikasyon

Kamag-anak na pamumuhunan

Nakapirming yugto na may mga clip

Manu-manong pagpoposisyon ng slide

Entry-level na pagtuturo

Mababa

Nakakabit na mekanikal na yugto

Nagdaragdag ng kinokontrol na paggalaw ng XY

Mga katugmang pag-upgrade ng mikroskopyo

Mababang–Katamtaman

Pinagsamang XY mekanikal na yugto

Kinokontrol na dalawang-axis na paggalaw

Karaniwang pagmamasid sa laboratoryo

Katamtaman

Rackless mekanikal na yugto

Binabawasan ang nakalantad na nakausli na mga bahagi ng rack

Madalas na paggamit ng laboratoryo

Katamtaman

Inverted microscope stage

Sinusuportahan ang mga sisidlan ng kultura at mga dalubhasang may hawak

Live na pagmamasid sa cell

Katamtaman–Mataas

Motorized XY stage

Programmable specimen na paggalaw

Automated imaging at pag-scan

Mataas

Yugto sa kapaligiran

Sinusuportahan ang kinokontrol na mga kundisyon ng sample

Matagal na live na pananaliksik sa cell

Mataas–Napakataas

Para sa mataas na dalas na regular na pagsusuri sa slide, ang pinagsamang XY na mekanikal na yugto ay karaniwang mas mainam kaysa sa manu-manong paglipat ng slide laban sa mga clip ng entablado.

Gayunpaman, ang motorized positioning ay hindi awtomatikong kinakailangan para sa bawat laboratoryo. Ang halaga nito ay depende sa kung kailangan ang programmable na paggalaw, repeatability o automation.

4.2 Tukuyin ang laki ng entablado mula sa saklaw ng paglalakbay ng XY

Ang isa sa mga pinakakaraniwang pagkakamali sa pagkuha ay ang paghahambing ng mga mekanikal na yugto lamang sa pamamagitan ng kanilang mga panlabas na sukat.

Inilalarawan ng panlabas na laki ng entablado ang sumusuportang platform, samantalang ang paglalakbay ng XY ay naglalarawan kung gaano kalayo talaga ang ispesimen na maaaring gumalaw sa bawat axis.

Halimbawa, ang isang yugto na may sukat na 140 × 140 mm na may hanay ng paglalakbay na 75 × 50 mm ay nagbibigay ng mas kaunting paggalaw kaysa sa maaaring imungkahi ng mga panlabas na sukat nito.

Isaalang-alang ang isang nakagawiang slide ng mikroskopyo na may sukat na humigit-kumulang 76 × 26 mm. Ang naaangkop na yugto ng paglalakbay ay depende sa aktwal na specimen-bearing region, slide holder geometry, optical center at kung ang kumpletong sample area ay kailangang i-scan.

Para sa mga workflow ng laboratoryo na nakabatay sa slide, ang hanay ng paglalakbay sa paligid ng 75 × 50 mm ay maaaring maging isang kapaki-pakinabang na panimulang detalye. Hindi ito dapat ituring bilang unibersal na minimum o patunay ng full-slide coverage.

Uri ng ispesimen

Pagsasaalang-alang sa pagbili ng yugto

Mga karaniwang slide ng mikroskopyo

XY travel at secure na slide holder

Malaking mga seksyon ng tissue

Sapat na accessible specimen area

Maramihang mga slide

Multi-slide holder at sapat na paglalakbay

Mga pagkaing petri

Compatible dish insert

Mga prasko ng kultura

Platform clearance at matatag na suporta sa sisidlan

Mga plato ng multiwell

Plate holder, travel range at well accessibility

Awtomatikong pag-scan ng slide

Motorized na pagpoposisyon at pagsasama ng software

Kapag bumili ng kapalit na yugto, humiling ng isang dimensional na pagguhit sa halip na umasa sa panlabas na sukat ng entablado lamang.

Distinguish stage size from X-Y travel range

4.3 Suriin ang katumpakan ng pagpoposisyon, pag-uulit at backlash

Para sa hinihingi na mga aplikasyon ng imaging, ang mga sumusunod na mekanikal na detalye ay hindi dapat malito.

Parameter

Ibig sabihin

Praktikal na kahalagahan

Saklaw ng paglalakbay

Pinakamataas na magagamit na paggalaw

Tinutukoy ang naa-access na specimen area

Resolusyon sa pagpoposisyon

Pinakamaliit na iniutos o ipinahiwatig na paggalaw, gaya ng tinukoy

Tinutukoy ang granularity ng pagpoposisyon

Katumpakan ng pagpoposisyon

Pagkakaiba sa pagitan ng nilalayon at aktwal na posisyon

Mahalaga para sa coordinate-based na imaging

Pag-uulit

Kakayahang bumalik nang tuluy-tuloy sa isang posisyon

Mahalaga para sa paulit-ulit na imaging

Backlash

Nawala ang paggalaw kapag binabaligtad ang direksyon

Nakakaapekto sa pagpoposisyon at pag-navigate

Drift

Unti-unting pagbabago sa posisyon sa paglipas ng panahon

Mahalaga para sa matagal na pagmamasid

Kapasidad ng pag-load

Sinusuportahang ispesimen at timbang ng may hawak

Mahalaga para sa mga dalubhasang sisidlan at silid

Halimbawa, maaaring mag-advertise ang isang supplier ng 1 μm na resolusyon ng paggalaw ng motor. Hindi ito nangangahulugan na ang yugto ay maaaring bumalik sa isang nakaraang posisyon sa loob ng 1 μm.

Ang disenyo ng encoder, mga mekanikal na pagpapaubaya, direksyon ng paggalaw, pagkarga, control software at mga kondisyon sa kapaligiran ay lahat ay nakakaimpluwensya sa aktwal na pagganap.

Ang teknikal na gawain ng Applied Scientific Instrumentation sa microscope stage repeatability ay nakikilala ang parehong direksyon na pagganap ng pagbalik mula sa pagganap ng pagbalik na kinasasangkutan ng mga pagbabago sa direksyon ng paggalaw. Ang mga ito ay iba't ibang mga katangian at dapat na talakayin nang hiwalay kapag sinusuri ang mga detalye ng yugto.

Paano nakakaapekto ang error sa pagpoposisyon sa pagmamasid sa cell?

Ipagpalagay na ang isang mikroskopyo ay may 40x na layunin at isang FN20 eyepiece.

Ang diameter ng field ng specimen-plane ay kinakalkula bilang:

Field Diameter = Field Number / Objective Magnification

Field Diameter = 20 / 40

Field Diameter = 0.5 mm = 500 μm

Kung ang repositioning error ay 20 μm, ang displacement na nauugnay sa diameter ng field ay maaaring kalkulahin gamit ang:

Relative Positioning Error (%) = (Positioning Error / Field Diameter) × 100%

Error sa Relative Positioning = (20 / 500) × 100%

Error sa Relative Positioning = 4%

Sa isang 100x na layunin at parehong eyepiece, bumababa ang lapad ng field:

Field Diameter = 20 / 100

Field Diameter = 0.2 mm = 200 μm

Ang parehong 20 μm positioning error ngayon ay kumakatawan sa:

Error sa Relative Positioning = (20 / 200) × 100%

Error sa Relative Positioning = 10%Numerical Aperture

Ang paghahambing ay maaaring ibuod tulad ng sumusunod:

Parameter

40 × layunin

100 × layunin

Numero ng field ng eyepiece

FN20

FN20

diameter ng specimen field

500 μm

200 μm

Ipinagpalagay na error sa pagpoposisyon

20 μm

20 μm

Kamag-anak na error sa pagpoposisyon

4%

10%

Relative Error Ratio = 10% / 4% = 2.5

Sa ilalim ng mga kundisyong ito sa pagkalkula, ang parehong error sa pagpoposisyon ay sumasakop ng 2.5 beses sa proporsyon ng diameter ng field kapag gumagamit ng 100× na layunin sa halip na isang 40× na layunin.

Ang displacement ay maaaring katanggap-tanggap para sa paglipat ng isang malaking rehiyon ng tissue ngunit may problema para sa pagsubaybay sa isang maliit na cell o intracellular na tampok.

Ito ay nagpapakita kung bakit ang katanggap-tanggap na pagpapaubaya sa pagpoposisyon ay dapat tukuyin ayon sa aktwal na laki ng ispesimen at gawain sa pagmamasid.

Ang nai-publish na pananaliksik ay nagbibigay din ng isang kapaki-pakinabang na benchmark para sa mga advanced na application. Ang isang 2022 na pag-aaral sa Journal of Cell Biology, na pinamagatang Quality Assessment in Light Microscopy for Routine Use Through Simple Tools and Robust Metrics, ay tumatalakay sa quantitative assessment ng microscope stage positioning, repeatability at iba pang katangian ng performance.

Ang nasabing pananaliksik ay naglalarawan ng mas mahigpit na mga kinakailangan na nauugnay sa advanced na automated microscopy. Ang pagganap ng pagpoposisyon sa grado ng pananaliksik ay hindi dapat bigyang-kahulugan bilang inaasahang pagganap ng mga ordinaryong manu-manong yugto ng mekanikal.

4.4 Kailan ka dapat mamuhunan sa isang de-motor na mekanikal na yugto?

Ang isang de-motor na yugto ay nagkakahalaga ng pagsasaalang-alang kapag ang laboratoryo ay kailangang magsagawa ng mga paulit-ulit na paggalaw sa mga paunang natukoy na lokasyon, kumuha ng mga magkakapatong na larawan para sa pagtahi o i-automate ang pagmamasid sa maraming sample.

Ang pangunahing komersyal na halaga nito ay hindi lamang mas mabilis na paggalaw. Nagbibigay-daan ito sa mga daloy ng trabaho na kung hindi man ay mangangailangan ng malaking manu-manong interbensyon.

Halimbawa, ang manu-manong pagmamasid sa 96 na balon sa isang microplate ay nagsasangkot ng paulit-ulit na paghahanap, pagpoposisyon at pagsusuri sa bawat balon. Maaaring i-automate ng isang katugmang motorized imaging system ang mga bahagi ng prosesong ito, lalo na kapag isinama sa positioning software at autofocus.

Gayunpaman, ang pagbili ng isang de-motor na entablado lamang ay hindi nagtatatag ng automated microscopy na kakayahan.

Ang kumpletong configuration ay maaari ding mangailangan ng isang katugmang controller, software interface, camera trigger synchronization, autofocus system at naaangkop na naka-calibrate na mga may hawak ng specimen.

Bago mag-order, kumpirmahin kung ang mga sangkap na ito ay kasama sa quotation o dapat bilhin nang hiwalay.

4.5 I-verify ang mechanical stage compatibility bago mag-order

Para sa mga kapalit na yugto at pag-upgrade ng mikroskopyo, humiling ng kumpirmasyon ng mounting interface, screw-hole spacing, taas ng platform, stage travel, condenser clearance at mga sukat ng specimen holder.

Ang isang yugto na nagpapataas ng specimen plane na lampas sa magagamit na hanay ng pagtutok ng mikroskopyo ay maaaring gawing hindi magagamit ang mga umiiral na layunin.

Para sa mga inverted microscope, ang pagbubukas ng entablado ay dapat ding magbigay ng sapat na clearance para sa mga layunin sa ilalim ng sample vessel.

OPTO EDU'sA54 Stage, Stand at Nosepiece kategoryaay nagbibigay ng isang entry point sa pagbili para sa mga mamimili na sinusuri ang mga bahagi ng makina ng mikroskopyo.

Dahil ang mga mekanikal na accessory ay maaaring partikular sa platform, dapat isumite ng mga mamimili ang modelo ng mikroskopyo, mga kasalukuyang larawan sa entablado at kinakailangang mga sukat ng specimen bago maglagay ng order.

5. Pinakamahusay na Microscope Accessories para sa Cell Observation

Ang pinakamahusay na mga accessory ng mikroskopyo para sa pag-obserba ng cell ay nakasalalay sa kung ang mga cell ay nabahiran o hindi nabahiran, naayos o nabubuhay, naka-mount sa mga slide o pinananatili sa mga sisidlan ng kultura.

Para sa mga nakagawiang stained cell, ang 20× o 40× plan achromatic na layunin, ang ipinares na 10× widefield na eyepiece at isang stable na mekanikal na yugto ay kadalasang isang cost-effective na configuration.

Para sa mga hindi nabahiran na buhay na mga cell, ang isang phase contrast optical system ay maaaring maghatid ng mas kapaki-pakinabang na pagpapabuti kaysa sa pagtaas ng layunin na magnification.

Para sa advanced na cellular imaging, mas mataas na NA layunin, angkop na mga bahagi ng fluorescence at precision positioning ay maaaring kailanganin.

5.1 Bakit nangangailangan ang iba't ibang uri ng cell ng iba't ibang accessory ng mikroskopyo

Ang pagmamasid sa cell ay maaaring magsama ng mga istruktura na may malawak na magkakaibang dimensyon at optical na katangian.

Biological specimen o istraktura

Tinatayang laki ng katangian

Iminungkahing paraan ng pagmamasid

Mga selula ng mammalian

10–30 μm, lubos na nagbabago

10×–40× layunin

Mga pulang selula ng dugo ng tao

7–8 μm

40 × o 100 × langis, depende sa detalye

Cell nuclei

Humigit-kumulang 5–10 μm

20×–40× layunin

Mga selula ng lebadura

Humigit-kumulang 3–10 μm

40× o 100× layunin

Maraming karaniwang bacteria

Humigit-kumulang 0.5–5 μm

100 × langis para sa detalyadong morpolohiya

Mitokondria

Humigit-kumulang 0.5–1 μm ang lapad, variable na haba

High-NA optics at angkop na contrast techniques

Mga ribosom

Humigit-kumulang 20–30 nm

Higit pa sa maginoo na resolution ng light microscope para sa indibidwal na detalye ng istruktura

Ang mga dimensyong ito ay tinatayang mga saklaw ng biyolohikal na sanggunian. Ang aktwal na laki ng cell ay nag-iiba ayon sa mga species, biological na estado at paghahanda ng ispesimen.

Ang mahalaga, ang kakayahang makakita ng isang istraktura ay hindi nangangahulugang ang mga panloob na tampok nito ay maaaring optically na malutas.

Halimbawa, ang isang fluorescently na may label na istraktura na mas maliit kaysa sa limitasyon ng resolution ng mikroskopyo ay maaari pa ring makita bilang isang punto ng liwanag. Ang paglutas ng panloob na morpolohiya nito ay nangangailangan ng iba't ibang kakayahan sa pag-imaging.

Samakatuwid, ang mga desisyon sa pagbili ay dapat isaalang-alang ang pinakamaliit na tampok na dapat makilala, hindi lamang ang kabuuang sukat ng cell.

5.2 Inirerekomendang mga pagsasaayos ng accessory ng mikroskopyo ayon sa aplikasyon

Aplikasyon

Mga inirerekomendang layunin

Eyepieces

entablado

Mga karagdagang accessories

Pangunahing edukasyon sa biology

4×, 10×, 40× Achromat

10×/18–20

Manu-manong XY

Brightfield condenser

Regular na stained cell observation

4×, 10×, 20×, 40× Plano

10×/20–22

Pinagsamang XY

Adjustable condenser

Pagsusuri ng blood smear

10×, 40×, 100× Langis

10×/20–22

Manu-manong katumpakan XY

Langis sa paglulubog

Microbiology

10×, 40×, 100× Langis

10 × malawak na larangan

Mekanikal na yugto

Angkop na paglamlam at pag-iilaw

Walang bahid na buhay na mga selula

10×, 20×, 40× Phase Contrast

10×/20–22

Stage na katugma sa ispesimen

Pagtutugma ng phase condenser

Adherent cell culture

10×, 20×, 40× LWD Phase Contrast

10 × malawak na larangan

Inverted microscope stage

Mga may hawak ng daluyan ng kultura

Fluorescence cell imaging

High-NA Plan na partikular sa application Fluorite o APO

Mga katugmang eyepieces

Precision o motorized na yugto

Pag-iilaw ng fluorescence at mga filter

Awtomatikong pagbibilang ng cell

10× o 20× Plano

Nakadepende sa aplikasyon

Naka-motor na XY

Camera at software ng pagsusuri

Ang mga pagsasaayos na ito ay inirerekomenda na mga panimulang punto sa halip na mga pangkalahatang detalye. Ang optical compatibility at ang nilalayong pang-eksperimentong pamamaraan ay dapat kumpirmahin bago ang pagkuha.

5.3 Pagpili ng mga accessory para sa mga stained at fixed cell

Ang mga fixed at stained na cell ay karaniwang nagbibigay ng sapat na contrast ng pagsipsip para sa conventional brightfield microscopy.

Ang pagsasaayos ng achromatic na layunin ng plano ay kadalasang praktikal na pagpipilian para sa mga nakagawiang obserbasyon dahil sinusuportahan nito ang pagsusuri ng specimen at digital na dokumentasyon nang hindi nangangailangan ng mga espesyal na sistema ng contrast.

Ang 10× na layunin ay maaaring gamitin upang matukoy ang mga kinatawan ng specimen na rehiyon, habang ang 20× at 40× na layunin ay nagbibigay ng progresibong mas detalyadong pagmamasid sa cellular morphology.

Dapat magdagdag ng 100× oil immersion na layunin kapag ang gawain sa pagmamasid ay nangangailangan ng mas mataas na kakayahan sa paglutas.

Para sa mga nakagawiang mamimili sa laboratoryo, ang pagsasaayos na ito ay maaaring mag-alok ng mas mahusay na balanse ng gastos, kakayahang magamit at pagpapanatili kaysa sa pagbili ng mga advanced na layunin sa pananaliksik para sa bawat workstation.

5.4 Pagpili ng mga aksesorya para sa hindi nabahiran na mga living cell

Ang mga buhay na selula ay kadalasang medyo transparent sa ilalim ng kumbensyonal na brightfield illumination.

Ang pagtaas ng magnification ay maaaring magmukhang mas malaki ang isang transparent na cell nang hindi sapat na nagpapabuti sa visibility ng mga hangganan o panloob na istruktura nito.

Tinutugunan ng phase contrast microscopy ang limitasyong ito sa pamamagitan ng pag-convert ng mga variation ng phase na ipinakilala ng specimen sa mga nakikitang pagkakaiba sa intensity.

Ang configuration ng phase contrast ay nangangailangan ng naaangkop na katugmang layunin ng phase at condenser annulus. Ang pagkakahanay sa pagitan ng mga optical na bahagi na ito ay kinakailangan para sa epektibong pagbuo ng contrast.

Para sa mga adherent cell na pinananatili sa mga culture dish o flasks, ang isang inverted microscope na may long-working-distance phase contrast na mga layunin ay kadalasang angkop na pagpipilian.

Bago bumili, dapat kumpirmahin ng mga mamimili:

  • Kultura ng daluyan ng materyal at kapal sa ilalim.

  • Layunin ang distansya sa pagtatrabaho at hanay ng pagwawasto.

  • Magagamit na mga phase contrast magnification.

  • Katugmang condenser annuli.

  • Pagkakatugma sa mga umiiral na microscope stand.

  • Kung kinakailangan ang kontrol sa temperatura o CO₂.

Ang huling pagsasaalang-alang ay nagiging partikular na mahalaga para sa pangmatagalang live na mga eksperimento sa cell, kung saan ang pagpapanatili ng angkop na mga biological na kondisyon ay maaaring mas mahalaga kaysa sa pagbili ng isang layunin na may karagdagang pagpapalaki.

Comparison of Different Optical Imaging Modalities for A549 Live Cells

Paghahambing ng Iba't ibang Optical Imaging Modalities para sa A549 Live Cells

5.5 Pagpili ng mga accessory para sa pagbibilang ng cell at quantitative imaging

Ipinakikilala ng quantitative imaging ang mga kinakailangan sa pagbili na higit pa sa kalidad ng visual na larawan.

Para sa pagbibilang ng cell, ang mga laboratoryo ay nangangailangan ng isang kilalang lugar ng pagmamasid o isang naka-calibrate na sukat ng digital na imahe. Ang mga layunin sa plano, angkop na mga adapter ng camera at matatag na pagpoposisyon ay nagiging partikular na mahalaga.

Dapat ding isaalang-alang ang pag-sample ng camera kung ang optical resolution ng layunin ay sapat na maitatala.

Ang epektibong specimen-plane pixel size ay kinakalkula gamit ang sumusunod na formula:

Effective Specimen-Plane Pixel Size = Sensor Pixel Size / (Objective Magnification × Camera Adapter Magnification)

Ipinapalagay ng kalkulasyong ito na walang karagdagang pag-magnify sa imaging path, pixel binning o digital image rescaling.

Halimbawa, isaalang-alang ang isang camera na may 3.45 μm na laki ng sensor pixel at isang 40× na layunin.

Pagkalkula para sa isang 0.5× camera adapter:

Epektibong Laki ng Pixel = 3.45 / (40 × 0.5)

Mabisang Laki ng Pixel = 3.45 / 20

Mabisang Laki ng Pixel = 0.1725 μm/pixel

Mabisang Laki ng Pixel ≈ 0.173 μm/pixel

Pagkalkula para sa isang 0.75× camera adapter:

Mabisang Laki ng Pixel = 3.45 / (40 × 0.75)

Mabisang Laki ng Pixel = 3.45 / 30

Mabisang Laki ng Pixel = 0.115 μm/pixel

Pagkalkula para sa isang 1× camera adapter:

Epektibong Laki ng Pixel = 3.45 / (40 × 1)

Mabisang Laki ng Pixel = 3.45 / 40

Mabisang Laki ng Pixel = 0.08625 μm/pixel

Mabisang Laki ng Pixel ≈ 0.086 μm/pixel

Pagpapalaki ng adapter ng camera

Epektibong specimen-plane pixel size

0.5×

0.173 μm/pixel

0.75×

0.115 μm/pixel

1×

0.086 μm/pixel

Gamit ang naunang pagkalkula ng teoretikal na resolusyon, ang isang 40 × / 0.65 NA layunin ay may tinantyang lateral na resolusyon na humigit-kumulang 0.52 μm sa 550 nm sa ilalim ng nakasaad na Rayleigh approximation.

d = (0.61 × λ) / NA

d = (0.61 × 0.55) / 0.65

d ≈ 0.516 μm ≈ 0.52 μm

Ang isang praktikal na paunang pagsusuri ng sampling ay ang paggamit ng isang epektibong laki ng pixel na hindi hihigit sa humigit-kumulang kalahati ng target na nareresolba na laki ng feature.

Epektibong Laki ng Pixel ≤ Target na Nareresolba na Laki ng Feature / 2

Maximum Effective na Laki ng Pixel ≈ 0.52 / 2

Maximum Effective na Laki ng Pixel ≈ 0.26 μm/pixel

Maaaring kailanganin ang mas mahigpit na pamantayan sa sampling depende sa optical transfer function at imaging modality.

Adaptor ng camera

Epektibong laki ng pixel

Preliminary sampling limit

Resulta

0.5×

0.173 μm/pixel

0.26 μm/pixel

Nakakatugon sa paunang pamantayan

0.75×

0.115 μm/pixel

0.26 μm/pixel

Nakakatugon sa paunang pamantayan

1×

0.086 μm/pixel

0.26 μm/pixel

Nakakatugon sa paunang pamantayan

Sa paglalarawang configuration na ito, ang 0.5× adapter ay nagbibigay ng medyo pinong sampling habang potensyal na nagbibigay-daan sa mas malaking field ng view ng camera kaysa sa isang 1× adapter.

Gayunpaman, ang aktwal na field ng camera ay nakasalalay din sa mga sukat ng sensor, disenyo ng adaptor at naitama na bilog ng imahe. Ang isang hindi angkop na adaptor ay maaaring magdulot ng pag-vignetting o pagkompromiso sa kalidad ng larawan sa gilid.

Ang pagkalkulang ito ay nagpapakita kung bakit ang pagbili ng mas mataas na megapixel na camera nang hindi sinusuri ang layunin at camera adapter ay maaaring hindi maghatid ng isang proporsyonal na pagtaas sa nalutas na biological na impormasyon.

6. Paano Balansehin ang Performance at Badyet Kapag Bumibili ng Microscope Accessories

Ang isang cost-effective na pagsasaayos ng mikroskopyo ay dapat na idinisenyo sa paligid ng kinakailangang pagganap sa halip na ang pinaka-advanced na magagamit na mga detalye.

Para sa mga laboratoryo na tumatakbo sa ilalim ng isang nakapirming badyet, ang naaangkop na priyoridad sa pamumuhunan ay nakasalalay sa dalas at pagiging kumplikado ng mga gawain sa pagmamasid.

6.1 Inirerekomendang mga priyoridad sa pamumuhunan ayon sa uri ng mamimili

Uri ng mamimili

Pinakamataas na priyoridad sa pamumuhunan

Pangalawang priyoridad

Mas mababang priyoridad maliban kung kinakailangan

Mga paaralan at unibersidad

Maaasahang mga layunin at matibay na mekanikal na bahagi

Kumportableng eyepieces

Advanced na optika ng pananaliksik

Mga karaniwang biological na laboratoryo

Magplano ng mga layunin at tumugma sa pag-iilaw

Matatag na yugto at mga accessory ng imaging

Motorized na pagpoposisyon

Mga laboratoryo ng microbiology

Angkop na 100× oil immersion optics

Condenser at katatagan ng entablado

Ultra-widefield na eyepieces

Mga laboratoryo ng cell culture

LWD phase contrast layunin

Stage na katugma ng sasakyang-dagat

Mga eyepiece na may mataas na pagpapalaki

Mga advanced na laboratoryo ng pananaliksik

Optical correction na tukoy sa application at NA

Precision positioning at imaging

Mga accessory para sa pangkalahatang layunin na walang kaugnayan sa mga eksperimento

Mga distributor ng mikroskopyo

Pagkakatugma, pagkakapare-pareho ng produkto at pagpapatuloy ng supply

Ang pagkakaroon ng kapalit at teknikal na dokumentasyon

Labis na bilang ng mga magkakapatong na configuration

Para sa mga laboratoryo na bumibili ng maraming mikroskopyo, ang mga standardized na accessory ay maaari ding bawasan ang pagiging kumplikado ng imbentaryo, mga kinakailangan sa pagsasanay ng operator at ang bilang ng mga kapalit na bahagi na dapat panatilihin.

6.2 Isaalang-alang ang kabuuang halaga ng pagmamay-ari

Ang pinakamababang presyo ng pagbili ay hindi kinakailangang kumakatawan sa pinakamababang pangmatagalang gastos sa kagamitan.

Ang pagtatasa sa pagbili ng accessory ng mikroskopyo ay dapat kasama ang paunang halaga ng produkto, kinakailangang mga adaptor, pag-install, pagkakalibrate, pagpapanatili, pagkakaroon ng kapalit at potensyal na pagkalugi na dulot ng downtime ng kagamitan.

Ang isang simpleng kabuuang halaga ng balangkas ng pagmamay-ari ay:

TCO = Cp + Ci + Cm + Cr + Cd

saan:

  • TCO = Kabuuang Halaga ng Pagmamay-ari.

  • Cp = Gastos sa pagbili.

  • Ci = Gastos sa pag-install at pagsasama, kasama ang mga kinakailangang adapter.

  • Cm = Gastos sa pagpapanatili.

  • Cr = Gastos sa pagpapalit.

  • Cd = Tinantyang gastos sa downtime.

Bilang kahalili, ang formula ay maaaring ipahayag bilang:

TCO = Gastos sa Pagbili + Gastos sa Pag-install at Pagsasama + Gastos sa Pagpapanatili + Gastos sa Pagpapalit + Gastos sa Downtime

Isaalang-alang ang sumusunod na paglalarawan ng tatlong taong paghahambing sa pagbili para sa pagsasaayos ng accessory sa laboratoryo.

item ng gastos

Configuration A

Configuration B

Paunang pagbili ng accessory

$300

$450

Mga karagdagang adapter

$80

$0

Pag-install at pagkakalibrate

$100

$50

Tinatayang pagpapanatili at pagpapalit

$150

$75

Tinantyang gastos sa downtime

$120

$50

Kabuuan ng tatlong taon

$750

$625

Ang kabuuang halaga ng pagmamay-ari para sa Configuration A ay:

TCO(A) = $300 + $80 + $100 + $150 + $120

TCO(A) = $750

Ang kabuuang halaga ng pagmamay-ari para sa Configuration B ay:

TCO(B) = $450 + $0 + $50 + $75 + $50

TCO(B) = $625

Ang pagtaas sa paunang halaga ng pagbili ay maaaring kalkulahin tulad ng sumusunod:

Paunang Pagtaas ng Halaga sa Pagbili (%) = [(Halaga sa Pagbili B − Halaga sa Pagbili A) / Halaga sa Pagbili A] × 100%

Paunang Pagtaas ng Gastos sa Pagbili = [($450 − $300) / $300] × 100%

Paunang Pagtaas ng Gastos sa Pagbili = ($150 / $300) × 100%

Pagtaas ng Gastos sa Paunang Pagbili = 50%

Ang pagbawas sa kabuuang halaga ng pagmamay-ari ay maaaring kalkulahin tulad ng sumusunod:

TCO Savings (%) = [(TCO A − TCO B) / TCO A] × 100%

TCO Savings = [($750 − $625) / $750] × 100%

TCO Savings = ($125 / $750) × 100%

TCO Savings ≈ 16.7%

Bagama't ang Configuration B ay may 50% na mas mataas na paunang presyo ng pagbili, ang modelong tatlong taong kabuuang gastos nito ay humigit-kumulang 16.7% na mas mababa.

Ang mga figure na ito ay hypothetical at hindi OPTO EDU quotation o sinusukat na gastos sa pagpapanatili. Dapat palitan ng mga mamimili ang mga ito ng sarili nilang mga sipi ng supplier, mga gastos sa paggawa at inaasahang paggamit ng kagamitan.

Ang prinsipyo ay partikular na nauugnay para sa mga distributor at institutional na mamimili na bumibili ng mga accessory sa dami.

7. Paano I-verify ang Kalidad ng Microscope Accessory Bago Bumili ng Maramihan

Ang isang mapagkakatiwalaang desisyon sa pagbili ay nangangailangan ng higit pa sa paghahambing ng mga detalye at mga larawan ng produkto. Para sa dami ng pagkuha, ang mga laboratoryo at mga distributor ay dapat magtatag ng mga pamantayan sa pagtanggap at suriin ang mga sample na kinatawan bago aprubahan ang isang malaking order.

7.1 Pagsusuri sa pagtanggap ng Objective lens

Dapat isaalang-alang ng Objective lens evaluation ang optical system sa kabuuan.

Ang isang naaangkop na pamamaraan ng pagsubok ay maaaring gumamit ng isang katugmang mikroskopyo, isang target na resolution, isang naka-calibrate na yugto ng micrometer at mga kinatawan ng biological specimens.

Test item

Iminungkahing paraan ng pag-verify

Aktwal na pagpapalaki

Naka-calibrate na stage micrometer at isang kilalang sukat ng imahe

Paglutas ng kakayahan

Angkop na target na pagsubok na may mataas na resolution o napatunayang pamamaraan ng pagsubok sa optical

patag na patlang

Ihambing ang sentro at peripheral na pokus gamit ang isang patag na ispesimen

Chromatic aberration

Suriin ang mga high-contrast na feature sa ilalim ng kontroladong pag-iilaw

Distansya sa pagtatrabaho

Kumpirmahin ang clearance sa focal plane

Parfocal na pagganap

Lumipat ng mga layunin at suriin ang kinakailangang muling pagtuon

Contrast performance

Obserbahan ang mga kinatawan ng biological specimens

Mechanical compatibility

Suriin ang mounting, nosepiece clearance at secure na pag-install

Maaaring gumamit ng target na resolusyon ng USAF 1951 o isa pang naka-calibrate na sanggunian sa resolusyon kung saan ang mga laki at kaibahan ng tampok nito ay angkop para sa layuning sinusuri.

Gayunpaman, ang target na resolution ng line-pair at ang Rayleigh criterion para sa point separation ay hindi eksaktong sinusukat ang parehong optical na katangian. Ang kanilang mga resulta ay hindi dapat direktang katumbas nang hindi isinasaalang-alang ang pamamaraan ng pagsukat.

7.2 Pagsubok sa pagtanggap ng eyepiece

Dapat kasama sa pagsusuri ng eyepiece ang aktwal na diameter ng field, center-to-edge na kalidad ng imahe, pagbaluktot ng imahe, pagkakapare-pareho ng binocular, pagiging tugma ng reticle at kaginhawaan sa panonood.

Maaaring gumamit ng stage micrometer o naka-calibrate na reference na slide para i-verify ang mga sukat ng field ng specimen-plane.

Para sa mga binocular system, dapat ding suriin ng mga user na ang parehong eyepiece ay gumagawa ng pare-parehong sukat ng imahe at kumportableng sabay na pagtingin.

Para sa maramihang mga order, dapat na isagawa ang mga kinatawan na pagsusuri gamit ang mga modelo ng mikroskopyo kung saan aktuwal na ikakabit ang mga eyepiece.

7.3 Pagsubok sa pagtanggap sa yugto ng mekanikal

Ang pagganap ng mekanikal na yugto ay dapat suriin sa ilalim ng inaasahang pagkarga ng ispesimen at mga kondisyon ng pagmamasid.

Kasama sa isang praktikal na manu-manong yugto ng pagsubok ang paglipat sa kumpletong hanay ng paglalakbay, pag-reverse ng direksyon kasama ang parehong mga palakol, pagbalik sa isang tampok na sanggunian at pagsusuri kung ang ispesimen ay nananatiling ligtas na nakaposisyon.

Para sa mga motorized na yugto, ang quantitative repeatability testing ay dapat isagawa gamit ang isang calibrated imaging system.

Halimbawa, maaaring tukuyin ng isang mamimili ang isang paunang pamamaraan ng pagtanggap na kinasasangkutan ng 20 paulit-ulit na paggalaw sa bawat axis, kabilang ang parehong mga diskarte sa parehong direksyon at pabalik na direksyon.

Ang sinusukat na paglilipat sa pagbalik ay dapat na ikumpara sa pagpapaubaya sa pagtanggap na partikular sa aplikasyon.

Ito ay isang iminungkahing procurement test procedure, hindi isang internationally standardized acceptance protocol.

Para sa mga wastong paghahambing, idokumento ang distansya ng paglalakbay, pag-load ng specimen, temperatura ng silid, layunin, pagkakalibrate ng imahe, direksyon ng paggalaw, oras ng pag-aayos at paraan ng pagkalkula ng error sa pagpoposisyon.

7.4 Humiling ng pansuportang dokumentasyon mula sa supplier

Dokumento sa pagbili

Bakit ito mahalaga

Teknikal na datasheet

Pagkumpirma ng pagiging tugma

Binabawasan ang mga maling desisyon sa pagbili

Dimensional na pagguhit

Bine-verify ang mekanikal na pag-install

Mga larawan sa pagsubok ng kinatawan

Sinusuportahan ang paunang pagsusuri sa optical

Ulat ng pagsubok na may mga kondisyon sa pagsukat

Tumutulong na magtatag ng kredibilidad sa pagganap

Batch na dokumentasyon ng inspeksyon

Sinusuportahan ang pagkakapare-pareho sa maramihang mga order

Pahayag ng warranty

Nililinaw ang saklaw at mga pagbubukod

Ang pagkakaroon ng mga kapalit na bahagi

Sinusuportahan ang pangmatagalang pagpapanatili ng kagamitan

Mga dokumento sa pagsunod na partikular sa produkto

Lead time at impormasyon ng supply

Sinusuportahan ang pag-iiskedyul ng proyekto

Para sa hinihingi na mga aplikasyon sa pananaliksik, ang mga pangkalahatang paghahabol sa marketing tulad ng mataas na katumpakan, mataas na resolution o propesyonal na kalidad ng optical ay hindi dapat palitan ang mga masusukat na detalye.

Kahit na ang mga may karanasang koponan sa pagbili ay maaaring makatagpo ng mga problema kapag ang mga accessory ay pinili nang independyente sa halip na bilang mga bahagi ng isang pinagsamang optical system.

Nagkamali sa pagbili

Potensyal na kahihinatnan

Inirerekomendang solusyon

Pagpili ng mga layunin sa pamamagitan lamang ng pagpapalaki

Mas malalaking larawan na walang karagdagang detalye

Ihambing ang NA at mga kinakailangan sa paglutas

Pagbili ng pinakamataas na-magnification eyepieces

Walang laman na magnification

Kalkulahin ang kapaki-pakinabang na pag-magnify

Paghahalo ng may hangganan at infinity na optika

Mga problema sa focus at aberasyon

Kumpirmahin ang pagiging tugma ng optical system

Pagpili ng mga layunin sa pamamagitan lamang ng pag-mount ng thread

Maling optical o mekanikal na pagganap

I-verify ang kumpletong interface

Hindi pinapansin ang kapal ng coverslip

Nabawasan ang contrast at resolution

Itugma ang layunin ng pagwawasto sa sample

Pagbili ng napakalaking-field na eyepieces

Vignetting o mahinang peripheral na kalidad ng imahe

Kumpirmahin ang sinusuportahang itinamang field

Nakakalito ang laki ng stage sa hanay ng paglalakbay

Hindi naa-access na mga rehiyon ng specimen

Humiling ng mga detalye ng paggalaw

Nakalilito ang resolution ng paggalaw na may repeatability

Hindi tumpak na pagpoposisyon ng pagbalik

Humiling ng sinusukat na data ng pagpoposisyon

Pagbili ng phase contrast na layunin nang walang katugmang condenser

Hindi epektibong pagpapahusay ng contrast

Bumili ng isang katugmang sistema ng phase

Paggamit ng hindi angkop na mga layunin para sa mga sisidlan ng kultura

Kawalan ng kakayahan upang maabot ang focus

I-verify ang kapal ng sisidlan at distansya sa pagtatrabaho

Pagbili ng maramihang dami nang walang sample validation

Paulit-ulit na pag-install at mga problema sa pagganap

Aprubahan muna ang mga sample na kinatawan

Hindi pinapansin ang mga kapalit na bahagi at warranty

Tumaas na pangmatagalang gastos sa pagpapanatili

Kumpirmahin ang suporta pagkatapos ng benta

Ang karamihan sa mga panganib sa pagbili na ito ay maaaring mabawasan sa pamamagitan ng pagdodokumento sa platform ng mikroskopyo, mga kinakailangan sa pagmamasid at kinakailangang mga interface ng accessory bago humiling ng mga sipi.

9. Saan Bumili ng Mga Katugmang Accessory ng Microscope: OPTO EDU

Kapag bumibili ng mga accessory ng mikroskopyo para sa paggamit ng institusyon, mga pag-upgrade sa laboratoryo o pamamahagi, ang pakikipagtulungan sa isang supplier na nauunawaan ang optical compatibility ay maaaring kasinghalaga ng pagpili ng accessory mismo.

Itinatag noong 2005, ang OPTO EDU (Opto-Edu Beijing Co., Ltd.) ay dalubhasa sa mga mikroskopyo, optical accessory at mga instrumentong pang-edukasyon.

Ayon sa na-publish na impormasyon ng kumpanya nito, ang supply network ng OPTO EDU ay may kasamang higit sa 150 mikroskopyo at mga tagagawa ng accessory, na may isang katalogo na sumasaklaw sa higit sa 2,100 mga modelo ng mikroskopyo at higit sa 3,400 mga instrumentong pang-edukasyon. Ang kumpanya ay nag-aalok ng application-based na pagpili ng produkto at nag-a-advertise ng tatlong taong microscope warranty, na napapailalim sa naaangkop na mga tuntunin ng produkto.

9.1 I-explore ang OPTO EDU microscope accessories

Ang microscope accessory catalog ng OPTO EDU ay sumasaklaw sa conventional biological microscopy pati na rin ang mga espesyal na optical technique. Maaaring galugarin ng mga mamimili ang mga nauugnay na kategorya ng produkto ayon sa kanilang mga kinakailangan sa pagmamasid.

Kategorya ng produkto

Magagamit na direksyon sa pagbili

Link ng produkto

A52 Layunin

Achromatic, plano, infinity-correct at espesyal na mga layunin

Galugarin ang Mga Layunin

A51 Eyepiece

Pagpili ng visual at tukoy sa application ng eyepiece

Galugarin ang Eyepieces

A54 Stage, Stand, Nosepiece

Mga mekanikal na bahagi at pag-upgrade ng mikroskopyo

I-explore ang Mechanical Accessories

A5 Microscope Accessories

Komprehensibong optical at mekanikal na pagpili ng accessory

Galugarin ang Lahat ng Accessory ng Microscope

A58 Micrometer

Mga accessory sa pagkakalibrate at pagsukat

Galugarin ang Micrometer

A5C Phase Contrast Accessories

Mga configuration ng contrast ng phase

I-explore ang Phase Contrast Accessories

A5F Fluorescent Accessories

Mga optika ng fluorescence na tukoy sa application

I-explore ang Fluorescent Accessories

9.2 Inirerekomenda ang serye ng layunin ng OPTO EDU upang suriin

Ang mga sumusunod na layuning pamilya ay nagbibigay ng mga panimulang punto para sa iba't ibang mga kinakailangan sa pagkuha.

OPTO EDU A52.2601 Achromatic na Layunin

achromatic objective

Isang opsyon upang suriin para sa pang-edukasyon na microscopy at regular na biological na pagmamasid kung saan ang pangunahing optical correction at pagbili ng gastos ay mahalagang mga pagsasaalang-alang.

OPTO EDU A52.2603 Layunin ng Plano

OPTO EDU A52.2603 Plan Objective

Isang kandidato para sa pagmamasid sa laboratoryo at mga aplikasyon ng digital imaging na nakikinabang sa pinahusay na field flatness.

OPTO EDU A52.2606 Layunin ng Infinity Plan

OPTO EDU A52.2606 Infinity Plan Objective

Inilaan para sa pagsusuri gamit ang isang katugmang infinity-corrected microscope system.

OPTO EDU A5C.2635 Infinity Plan LWD Semi-APO Positive Phase Contrast at Brightfield Objective

OPTO EDU A5C.2635 Infinity Plan LWD Semi-APO Positive Phase Contrast and Brightfield Objective

Isang espesyal na layunin ng pamilya na susuriin para sa mga aplikasyon tulad ng phase contrast observation na nangangailangan ng pinahabang distansya sa pagtatrabaho, napapailalim sa microscope at specimen vessel compatibility.

OPTO EDU A5F.2635 Infinity Plan LWD Semi-APO Fluorescent Objective

OPTO EDU A5F.2635 Infinity Plan LWD Semi-APO Fluorescent Objective

Isang opsyon upang suriin para sa mga dalubhasang daloy ng trabaho sa fluorescence imaging na nangangailangan ng mahabang distansya sa pagtatrabaho.

Ang mga partikular na opsyon sa pag-magnify, mga numerical na aperture, mga distansya sa pagtatrabaho, mga sukat ng pag-mount at pagiging tugma ay dapat kumpirmahin sa pamamagitan ng kaukulang mga teknikal na datasheet bago mag-order.

9.3 Anong impormasyon ang dapat mong ibigay kapag humihiling ng isang panipi?

Ang pagbibigay ng detalyadong impormasyon sa aplikasyon ay nagbibigay-daan sa supplier na magrekomenda ng mas naaangkop na pagsasaayos at binabawasan ang hindi kinakailangang komunikasyon sa panahon ng pagkuha.

Kinakailangang impormasyon

Halimbawa

Umiiral na modelo ng mikroskopyo

Manufacturer at kumpletong numero ng modelo

Uri ng mikroskopyo

Patayong biological o inverted microscope

Uri ng ispesimen

May bahid na tissue, bacteria o buhay na mga selula

Teknik sa pagmamasid

Brightfield, phase contrast o fluorescence

Kinakailangang magnification

4×, 10×, 20×, 40× o 100×

Optical system

Finite o infinity-corrected

Kinakailangang resolusyon

Pinakamaliit na tampok na dapat makilala

Sample na lalagyan

Slide, culture dish, flask o well plate

Mga kinakailangan sa yugto ng mekanikal

Pagpaparaya sa paglalakbay, pag-mount at pagpoposisyon

Mga kinakailangan sa imaging

Visual na pagmamasid, pagkuha ng litrato o pagsusuri ng imahe

Dami ng pagbili

Indibidwal na kapalit, institusyonal na order o pakyawan

Mga karagdagang kinakailangan

Packaging, dokumentasyon ng pagsunod at iskedyul ng paghahatid

Makipag-ugnayan sa OPTO EDU para sa Microscope Accessory Recommendations and Quotations

10. Mga Madalas Itanong Tungkol sa Pagpili ng Mga Accessory ng Microscope

Q: Ano ang pinakamahalagang accessory ng mikroskopyo?

A:

Q: Anong objective lens ang pinakamainam para sa pag-obserba ng mga cell?

A:Ang 20× o 40× na layunin ay karaniwang angkop para sa karaniwang pagmamasid sa morpolohiya ng cell. Maaaring kailanganin ang 100× oil immersion na layunin para sa detalyadong pagmamasid sa mga nabahiran na bakterya o mas pinong mga istraktura. Para sa mga hindi nabahiran na buhay na mga cell, ang mga layunin ng phase contrast ay kadalasang mas angkop kaysa sa simpleng pagtaas ng magnification.

Q: Mas maganda ba ang 20× eyepiece kaysa sa 10× eyepiece?

Hindi naman kailangan. Ang isang 20× eyepiece ay nagpapataas ng kabuuang visual magnification ngunit maaaring hindi mapabuti ang nalutas na detalye. Para sa maraming biological microscope, ang 10x widefield na eyepiece ay nagbibigay ng mas mahusay na pangkalahatang layunin na balanse ng kapaki-pakinabang na pag-magnify, saklaw ng field at kaginhawaan sa panonood.

T: Ano ang pagkakaiba sa pagitan ng achromatic at plan achromatic na mga layunin?

A:Ang mga layunin ng achromatic na plano ay nagsasama ng field-curvature correction bilang karagdagan sa achromatic correction. Ang mga ito ay partikular na kapaki-pakinabang kapag ang isang mas malaking flat specimen area ay dapat manatiling nakatutok, tulad ng digital imaging at sistematikong pagsusuri sa slide. Ang kanilang aktwal na resolution ay nakadepende pa rin sa numerical aperture at optical system performance.

T: Maaari ba akong gumamit ng mga layunin mula sa iba't ibang tatak ng mikroskopyo?

A:Minsan, ngunit kailangang ma-verify ang pagiging tugma. Ang mga layunin na may magkatulad na mga thread ay maaaring may iba't ibang mga kinakailangan sa optical correction, mga detalye ng tube lens, mga parfocal na distansya at mga mekanikal na dimensyon. Hindi ginagarantiyahan ng pisikal na pag-install ang tamang pagganap ng imaging.

T: Maaari ba akong magdagdag ng mekanikal na yugto sa isang umiiral nang mikroskopyo?

A:Oo, kung sinusuportahan ng mikroskopyo ang isang katugmang nakakabit o kapalit na mekanikal na yugto. Ang mga sukat ng pag-mount, taas ng ispesimen, clearance ng condenser at hanay ng pagtutok ay dapat suriin bago bumili.

Q: Kailangan ba ang isang motorized microscope stage para sa cell observation?

A:Hindi. Ang isang stable na manu-manong XY mekanikal na yugto ay sapat para sa karamihan ng mga regular na obserbasyon ng cell. Ang mga motorized na yugto ay mas angkop para sa awtomatikong pag-scan, multiposition imaging, paulit-ulit na pagsubaybay sa cell at iba pang mga application na nangangailangan ng programmable na paggalaw.

T: Anong mga accessory ng mikroskopyo ang kailangan para sa live cell observation?

A:Ang isang karaniwang pagsasaayos ng live cell observation ay maaaring magsama ng mga long-working-distance na layunin, katugmang phase contrast accessories, angkop na culture vessel holder at isang inverted microscope platform. Ang mga pinahabang eksperimento ay maaaring mangailangan din ng temperatura sa kapaligiran at kontrol ng CO₂.

Q: Ang mas mataas na numerical aperture ba ay palaging gumagawa ng mas magagandang larawan?

A:Ang mas mataas na NA ay nagpapabuti sa teoretikal na kakayahan sa paglutas sa ilalim ng angkop na mga optical na kondisyon. Gayunpaman, ang maling kapal ng coverslip, hindi angkop na immersion media, hindi sapat na pag-iilaw o hindi magandang paghahanda ng ispesimen ay maaaring pumigil sa kakayahang iyon na maisakatuparan. Samakatuwid, ang pagpili ng layunin ay dapat isaalang-alang ang kumpletong sistema ng imaging.

T: Paano ko mababawasan ang halaga ng maramihang pagbili ng microscope accessory?

A:I-standardize ang mga compatible na configuration ng accessory, piliin ang mga optical correction grade ayon sa aktwal na mga pangangailangan ng application, i-verify ang mga sample na kinatawan bago ang maramihang pag-order at kumpirmahin ang availability ng kapalit at mga tuntunin ng warranty. Ang pagsusuri sa kabuuang halaga ng pagmamay-ari ay kadalasang mas epektibo kaysa sa paghahambing ng mga presyo ng pagbili lamang.

Konklusyon

Ang pagpili ng mga tamang accessory ng mikroskopyo ay sa huli ay isang desisyon sa pagbili sa antas ng system.

Dapat piliin ang mga Objective lens ayon sa kinakailangang resolution, numerical aperture, optical correction at specimen na kondisyon. Ang mga eyepiece ay dapat magbigay ng naaangkop na kapaki-pakinabang na pag-magnify at saklaw ng field. Ang mga mekanikal na yugto ay dapat tumugma sa kinakailangang paggalaw ng ispesimen, katatagan ng pagpoposisyon at daloy ng trabaho.

Para sa karamihan ng mga nakagawiang aplikasyon sa pagmamasid sa cell, ang balanseng pagsasaayos na binubuo ng 10× widefield na eyepiece, 10×–40× na mga layunin sa plano at isang maaasahang XY mechanical stage ay nag-aalok ng malaking praktikal na halaga. Dapat ipakilala ang mga espesyal na accessory kapag ang application ay nangangailangan ng pinahusay na contrast, mas pinong resolution, mas malaking distansya sa pagtatrabaho o awtomatikong pagpoposisyon.

Ang pinaka-cost-effective na pagsasaayos ng accessory ng mikroskopyo ay hindi nangangahulugang ang pinakamurang o ang pinaka-advanced. Ito ang pagsasaayos na patuloy na nakakatugon sa mga kinakailangang kondisyon sa pagmamasid at pagsukat habang nananatiling tugma, napapanatili at napapanatiling matipid.

Sa malawak nitong mikroskopyo at katalogo ng accessory, sinusuportahan ng OPTO EDU ang mga laboratoryo, institusyong pang-edukasyon at mga distributor sa pagpili ng angkop na optical at mekanikal na mga bahagi para sa iba't ibang aplikasyon ng microscopy.

Kailangan ng tulong sa pagpili ng mga katugmang accessory ng mikroskopyo?

Talakayin ang Iyong Microscope Accessory na Kinakailangan sa OPTO EDU

online na serbisyo

online na serbisyo
Nandito kami online para suportahan!

Ipadala ang Mensahe

*
*
*
*
*
7
close
7

Service

Scan the QR code Close
qr code

Inquiry Basket

Walang laman ang data

PAGKUMPARAHIN ANG MGA PRODUKTO

Walang laman ang data

Mga Advanced na Setting ng Cookie

Mahahalagang Cookies

Ang mga cookies na ito ay nagbibigay-daan sa pangunahing functionality tulad ng seguridad, pag-verify ng pagkakakilanlan at pamamahala ng network. Hindi maaaring i-disable ang cookies na ito.

Paganahin ang Marketing Cookies

Ginagamit ang cookies na ito upang subaybayan ang pagganap ng advertising, pagpayag sa pagpapadala ng data ng user na nauugnay sa advertising sa Google, at pagpayag para sa website na maghatid ng personalized na pag-advertise upang magbigay ng mga mas nauugnay na serbisyo.

Paganahin ang Functional Cookies

Nangongolekta ng data ang cookies na ito para matandaan ang mga pagpipiliang ginagawa ng mga user para mapabuti at magbigay ng mas personalized na karanasan.

Paganahin ang Analytics Cookies

Tinutulungan kami ng cookies na ito na maunawaan kung paano nakikipag-ugnayan ang mga bisita sa aming website, tumuklas ng mga error at magbigay ng mas mahusay na pangkalahatang analytics.

Hindi maaaring i-disable ang mahahalagang cookies.