



Transmit/Reflect Illumination Switch Knob The illumination control knobs to switch transmit / epi-fluorescent reflect illumination are located on the right side of main body, for easy operation | Medial Changeable Lens With built-in turret structure, 1x and 1.5x lens can be changed accordingly |
4.3“ LCD Information Touch Screen(A16.1097) --Show Objectives In Use In Nosepiece --Show Cubes In Use In Multi Function Turret --Brightness Memorize & Restore Function --Touch To Adjust Brightness --Touch To Set The System | |

Trinocular Head With Built-in Bertrand Lens The built-in bertrand lens can observe the pupil of the objective lens when moving into the light path, and act as a centering telescope Flexible Transmit Illuminator With retroverted Illuminator, thereby ensuring large space for operation and sample exchange Long Working Distance Turret Condenser LWD turret structure, with 6 positions for phase contrast annulus, DIC annulus, & bright field view, meets various test needs. condenser N.A.0.55, W.D.26mm |

Camera Adapter At Both Sides & Trinocular Head The optical path output selection dial can distribute the optical images to different ports, providing expansion space for more optical image applications |


Simple And Fast Operation, Iris Slider Reflective field diaphragm, aperture diaphragm and filter plate, three different types of diaphragm sliders show the versatility of A16.1090 in in vivo cell research. When the aperture diaphragm and the fluorescence filter insert are used together, the fluorescence intensity can be adjusted to the most ideal according to the selected fluorescence module and objective lens |


Fluorescent Turret Fluorescence excitation module turntable type: easier and more flexible It adopts multifunctional six-station turntable structure: it can be easily taken out from the host, and it is convenient to replace various fluorescence excitation modules |






◆Bright Field Observation Unique infinity optical system, combined with semi-apochromatic fluorescent objective lens, effectively eliminates field curvature, chromatic aberration, spherical aberration, coma and other imaging problems, the image is brighter, all magnifications can achieve higher super-resolution and flat type |

◆Phase Contrast Observation Phase contrast is an optical contrast technology that uses a phase contrast objective lens and a condenser ring. The high-efficiency halogen lamp can provide a bright light source and obtain clear images even at high magnification |





| A14.1090 Research Level Inverted Biological Microscope | A14.1096 | A14.1097 | A16.1096 | A16.1096 | A16.1098 | Cata.No. | |
| Optical System | NIS60 Infinite Optical System, Semi-APO | ● | ● | ● | ● | ● | |
| Observation Method | Bright Field | ● | ● | ● | ● | ● | |
| Dark Field | - | - | ○ | ○ | ○ | ||
| Phase Contrast | ● | ● | ● | ● | ● | ||
| Polarizing | ○ | ○ | ○ | ○ | ○ | ||
| Flourescent | ○ | ○ | ● | ● | ● | ||
| DIC | ○ | ○ | ○ | ○ | ○ | ||
| LCD Screen | 4.3"LCD Information Touch Screen In Front of Main Body, For Easy Use in Dark Working Condition. --Show Objectives In Use In Nosepiece --Show Cubes In Use In Multi Function Turret --Brightness Memorize & Restore Function --Touch To Adjust Brightness --Touch To Set The System | - | ● | - | ● | ○ | |
| Head | Seidentopf Trinocular Head, Inclined 45°, Interpupillary Distance 47-78mm, Ligth Split Switch E100:P0/E20:P80/E0:P100, With Built-in BertrandLens Which Can Be Used As Centering Telescope | ● | ● | ● | ● | ● | |
| Eyepiece | SW10x/25mm, High Eyepoint, Diopter Adjustable, Dia.30mm | ○ | ○ | ○ | ○ | ○ | A51.1090-1025 |
| SW10x/22mm, High Eyepoint, Diopter Adjustable, Dia.30mm | ● | ● | ● | ● | ● | A51.1090-1022 | |
| EW12.5x/17.5mm, High Eyepoint, Diopter Adjustable, Dia.30mm | ○ | ○ | ○ | ○ | ○ | A51.1090-12516 | |
| WF15x/16mm, High Eyepoint, Diopter Adjustable, Dia.30mm | ○ | ○ | ○ | ○ | ○ | A51.1090-1516 | |
| WF20x/12mm, High Eyepoint, Diopter Adjustable, Dia.30mm | ○ | ○ | ○ | ○ | ○ | A51.1090-2012 | |
| Media Lens | Built-in Media Lens Turret 1.0x, 1.5x, Under Nosepiece | ● | ● | ● | ● | - | |
| Built-in Media Lens Turret 1.0x, 1.5x. CF, Under Nosepiece | - | - | - | - | ● | ||
| Nosepiece | Manual Sextuple Nosepiece, With DIC Slot | ● | - | ● | - | - | |
| Coded Manual Sextuple Nosepiece, With DIC Slot | - | ● | - | ● | - | ||
| Motorized Coded Manual Sextuple Nosepiece, With DIC Slot, With Objective Protection Function When Switch The Objectives | - | - | - | - | ● | ||
| N-iPLFN PH Infinity Plan Semi-APO Phase Contrast Objective | 4x/0.13, W.D.16.5mm, No Cover Glass | ○ | ○ | ○ | ○ | ○ | A5C.1098-4 |
| 10x/0.30, W.D.7.4mm, Cover Glass 1.2mm | ● | ● | ● | ● | ● | A5C.1098-10 | |
| 20x/0.45, W.D.7.5-8.8mm, Cover Glass 0-2mm, With Built-in Correct Ring | ● | ● | ● | ● | ● | A5C.1098-20 | |
| 40x/0.6, W.D.3-4.4mm, Cover Glass 0-2mm, With Built-in Correct Ring | ● | ● | ● | ● | ● | A5C.1098-40 | |
| 60x/0.75, W.D.1.8-2.6mm, Cover Glass 0.1-1.3mm, With Built-in Correct Ring | ○ | ○ | ○ | ○ | ○ | A5C.1098-60 | |
| Focusing | Coaxial Coarse & Fine Focusing, Focusing Range 9mm (Up 7mm, Down 2mm), Coarse Stroke 2mm, Fine Stroke 0.2mm | ● | ● | ● | ● | - | |
| Motorized Z Axies (Optical Grating Type) Focusing System, Focusing Range 9mm (Up 7mm, Down 2mm), Focusing Resloution 0.02um With Optical Grating, Movement Repeat Positioning Accuracy +/-0.1um, Prevent Stage Fall Down Function | - | - | - | - | ● | ||
| Working Stage | Three Layer Mechnical Stage, Moving Range 130x85mm, Flexible Knob, Available For Different Size Small Stage Mounted on Top Layer | ● | ● | ● | ● | - | A54.1098 |
| Dia.38mm Holder For Slide & Petri Dish | ● | ● | ● | ● | - | A54.1098-38 | |
| Dia.54mm Holder For Petri Dish | ● | ● | ● | ● | - | A54.1098-54 | |
| 96 Holes Plate Holder | ● | ● | ● | ● | - | A54.1098-96 | |
| Terasaki Holder | ● | ● | ● | ● | - | A54.1098-TH | |
| Universal Holder | ● | ● | ● | ● | - | A54.1098-UH | |
| Motorized X/Y Axies (Optical Grating Type) Mechanical Stage, Size 325x144mm, Moving Range 130x100mm, Max Speed 10mm/s, Resolution 0.1um, Repeat Accuracy +/-0.5um, Available For Different Size Small Stage Mounted on Top Layer, With Separate Communication/Main Control Box & Stick | - | - | - | - | ● | A54.1098-M | |
| Sample Holder, For Motorized Stage | - | - | - | - | ● | A54.1098-M1 | |
| 96 Holes Plate Holder, For Motorized Stage | - | - | - | - | ● | A54.1098-M2 | |
| 6 Holes Petri Dish Holder, For Motorized Stage | - | - | - | - | ● | A54.1098-M3 | |
| Condenser | Long Working Distance Turret Condenser, N.A.0.55, W.D.26mm, With 6 Positions For Phase Contrast Annulus, DIC Annulus, And Bright Field View | ● | ● | ● | ● | - | A56.1098 |
| MotorizedLong Working Distance Turret Condenser, N.A.0.55, W.D.26mm, With 6 Positions For Phase Contrast Annulus, DIC Annulus, And Bright Field View | - | - | - | - | ● | A56.1098-M | |
| Multi Function Turret | Multi Function Turret Under Nosepice, With 6 Positions For Cubes Of Bright Field, Dark Field, Phase Contrast, Polarizing, Fluorescent View, Turning The Disc To Easily Switch Observation Methods | ● | ● | ● | - | - | |
| CodedMulti Function Turret Under Nosepice, With 6 Positions For Cubes Of Bright Field, Dark Field, Phase Contrast, Polarizing, Fluorescent View, Turning The Disc To Easily Switch Observation Methods | - | - | - | ● | - | ||
| Motorized Coded Multi Function Turret Under Nosepice, With 6 Positions For Cubes Of Bright Field, Dark Field, Phase Contrast, Polarizing, Fluorescent View, Turning The Disc To Easily Switch Observation Methods | - | - | - | - | ● | ||
| Dark Field | Dark Field Block, Put In Multi Function Turret, For Reflect Light Source | ○ | ○ | ○ | ○ | ○ | A5D.1098 |
| Polarizing For Transmit Light | Polarizer Filter On LWD Turret Condenser | ○ | ○ | ○ | ○ | ○ | A5P.1098-P |
| Analyzer Slide, Insert Into Slot On Nosepiece, 360° Rotatable | ○ | ○ | ○ | ○ | ○ | A5P.1098-A | |
| Polarizing For Reflect Light | Polarizer Light Block, Put In Multi Function Turret | ○ | ○ | ○ | ○ | ○ | A5P.1098-PL |
| Circularly Polarized Light Block, Put In Multi Function Turret | ○ | ○ | ○ | ○ | ○ | A5P.1098-CP | |
| Phase Contrast | Phase Contrast Annulus 10x/20x, Put In Turret Condenser | ● | ● | ● | ● | ● | A5C.1096-1020 |
| Phase Contrast Annulus 40x, Put In Turret Condenser | ● | ● | ● | ● | ● | A5C.1096-40 | |
| Phase Contrast Annulus 60x, Put In Turret Condenser | ○ | ○ | ○ | ○ | ○ | A5C.1096-60 | |
| DIC | DIC Full Set, For A14.109, A16.109 Series --Transmit DIC Sliders 10x20x40x60x, Insert Under Nosepiece --Transmit DIC Prism 10x20x40x60x, Put Into LWD Condenser Disc --Polarizing Analyizer 360° Rotateable | ○ | ○ | ○ | ○ | ○ | A5C.1097 |
| Illumniation | Transmit/Reflect Illumnation Switch Knob, On Right Side Of Main Body, Press To Switch Transmit And Reflect Switch Light Quickly | ● | ● | ● | ● | ● | |
| Transmit Light Source | 12V100W Halogen Kohler Illumination, Brightness Adjustable, Flexible Illuminator Body Can Retrovert From Optical Path For Large Space of Operation And Sample Exchange | ● | ● | ● | ● | ● | A56.1095-12V100W |
| 10W S-LED Kohler Illumination, Brightness Adjustable | ○ | ○ | ○ | ○ | ○ | A56.1095-10WLED | |
| Reflect Light Source | Large Filter Holder Slide With 3 Holes | ○ | ○ | ● | ● | ● | A56.1095-LS |
| Field Diaphram Slide, Center Adjustable, | ○ | ○ | ● | ● | ● | A56.1095-FS | |
| Small Empty Slide | ○ | ○ | ● | ● | ● | A56.1095-ES | |
| Aperture Diaphragm Slide | ○ | ○ | ● | ● | ● | A56.1095-AS | |
| Netural Filter | ○ | ○ | ● | ● | ● | A56.1095-NE | |
| ReflectFluorescent Light Source | Reflect 100W Osram Mercury HBO Fluorescent Light House Intelligent Power Supply Control Box With Barrier To Stop/Recover Fluorescent Illumination Quickly | ○ | ○ | ● | ● | ● | A5F.1095-100W |
| 10W S-LED Fluorescent Light, 4 Color Bands, Brightness Adjustable By Control Box | ○ | ○ | ○ | ○ | ○ | A5F.1095-10WLED | |
| 75W Metal Halide Light Source, Life Time 2000 Hours | ○ | ○ | ○ | ○ | ○ | A5F.1095-75WM | |
| Fluorescent Filter B Block, Put In Multi Function Turret | ○ | ○ | ● | ● | ● | A5F.1095-B | |
| Fluorescent Filter G Block, Put In Multi Function Turret | ○ | ○ | ● | ● | ● | A5F.1095-G | |
| Fluorescent Filter U Block, Put In Multi Function Turret | ○ | ○ | ● | ● | ● | A5F.1095-U | |
| Fluorescent Filter V Block, Put In Multi Function Turret | ○ | ○ | ○ | ○ | ○ | A5F.1095-V | |
| Metallurgical | Upgrade To A13.1090Inverted Metallurgical Microscope | ○ | ○ | ○ | ○ | ○ | A13.1090 |
| Adapter | 3 Camera Ports, On Both Side Of Main Body And Head, Turret Switch Between: --Trinocular Port Switch E100:P0/E20:P80/E0:P100 --Left Port C-Mount 1.0x E0:P100 --Right Port C-Mount 1.0x E20:P80 | ● | ● | ● | ● | ● | |
| C-Mount 0.4x | ○ | ○ | ○ | ○ | ○ | A55.1095-04 | |
| C-Mount 0.5x | ○ | ○ | ○ | ○ | ○ | A55.1095-05 | |
| C-Mount 1.0x | ● | ● | ● | ● | ● | A55.1095-10 | |
| Software | NOMIS Basic Image Processiing Software | ○ | ○ | ○ | ○ | ○ | A30.1090 |
| Note:"●"In Table Is Standard Outfits,"○"Is Optional Accessories"-"Is Unavailable | |||||||





Español
English
Pусский
Français
Portugues
Deutsch
lingua italiana
العربية
Melayu
Filipino
Монгол хэл
dansk
Bahasa indonesia
日本語
한국어
Türk dili
Tiếng Việt
svenska
Nederlands
Norsk språk

Huang Xin